Literature DB >> 24177176

Model-Driven Safety Analysis of Closed-Loop Medical Systems.

Miroslav Pajic1, Rahul Mangharam, Oleg Sokolsky, David Arney, Julian Goldman, Insup Lee.   

Abstract

In modern hospitals, patients are treated using a wide array of medical devices that are increasingly interacting with each other over the network, thus offering a perfect example of a cyber-physical system. We study the safety of a medical device system for the physiologic closed-loop control of drug infusion. The main contribution of the paper is the verification approach for the safety properties of closed-loop medical device systems. We demonstrate, using a case study, that the approach can be applied to a system of clinical importance. Our method combines simulation-based analysis of a detailed model of the system that contains continuous patient dynamics with model checking of a more abstract timed automata model. We show that the relationship between the two models preserves the crucial aspect of the timing behavior that ensures the conservativeness of the safety analysis. We also describe system design that can provide open-loop safety under network failure.

Entities:  

Keywords:  closed-loop medical systems; model-based development; safety analysis

Year:  2012        PMID: 24177176      PMCID: PMC3810414          DOI: 10.1109/TII.2012.2226594

Source DB:  PubMed          Journal:  IEEE Trans Industr Inform        ISSN: 1551-3203            Impact factor:   10.215


  5 in total

1.  Improving medical protocols by formal methods.

Authors:  Annette ten Teije; Mar Marcos; Michel Balser; Joyce van Croonenborg; Christoph Duelli; Frank van Harmelen; Peter Lucas; Silvia Miksch; Wolfgang Reif; Kitty Rosenbrand; Andreas Seyfang
Journal:  Artif Intell Med       Date:  2006-01-11       Impact factor: 5.326

2.  Plug-and-play for medical devices: experiences from a case study.

Authors:  David Arney; Sebastian Fischmeister; Julian M Goldman; Insup Lee; Robert Trausmuth
Journal:  Biomed Instrum Technol       Date:  2009 Jul-Aug

3.  Morphine in postoperative patients: pharmacokinetics and pharmacodynamics of metabolites.

Authors:  Jean Xavier Mazoit; Karin Butscher; Kamran Samii
Journal:  Anesth Analg       Date:  2007-07       Impact factor: 5.108

4.  Plug-and-play in the operating room of the future.

Authors:  Julian M Goldman; Richard A Schrenker; Jennifer L Jackson; Susan F Whitehead
Journal:  Biomed Instrum Technol       Date:  2005 May-Jun

5.  Programmable infusion pumps in ICUs: an analysis of corresponding adverse drug events.

Authors:  Teryl K Nuckols; Anthony G Bower; Susan M Paddock; Lee H Hilborne; Peggy Wallace; Jeffrey M Rothschild; Anne Griffin; Rollin J Fairbanks; Beverly Carlson; Robert J Panzer; Robert H Brook
Journal:  J Gen Intern Med       Date:  2008-01       Impact factor: 5.128

  5 in total
  5 in total

1.  A Novel Interoperable Safety System for Improved Coordination and Communication in Cardiac Surgery.

Authors:  David Arney; Geoffrey Rance; Srey Rithy; Julian M Goldman; Marco A Zenati
Journal:  OR 2.0 Context Aware Oper Theaters Comput Assist Robot Endosc Clin Image Based Proced Skin Image Anal (2018)       Date:  2018-10-02

2.  Dependability enhancing mechanisms for integrated clinical environments.

Authors:  Wenbing Zhao; Mary Q Yang
Journal:  J Supercomput       Date:  2017-03-29       Impact factor: 2.474

3.  Intelligent and Dynamic Ransomware Spread Detection and Mitigation in Integrated Clinical Environments.

Authors:  Lorenzo Fernández Maimó; Alberto Huertas Celdrán; Ángel L Perales Gómez; Félix J García Clemente; James Weimer; Insup Lee
Journal:  Sensors (Basel)       Date:  2019-03-05       Impact factor: 3.576

Review 4.  A Survey on Security and Privacy in Emerging Sensor Networks: From Viewpoint of Close-Loop.

Authors:  Lifu Zhang; Heng Zhang
Journal:  Sensors (Basel)       Date:  2016-03-26       Impact factor: 3.576

5.  A Model-Based Approach to Support Validation of Medical Cyber-Physical Systems.

Authors:  Lenardo C Silva; Hyggo O Almeida; Angelo Perkusich; Mirko Perkusich
Journal:  Sensors (Basel)       Date:  2015-10-30       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.