Literature DB >> 24174862

Dual-site right ventricular and left ventricular pacing in a patient with left ventricular systolic dysfunction and atrial fibrillation using a standard CRT-D device.

David Chase1, Vipin Kumar, Amit Hooda.   

Abstract

UNLABELLED: In patients undergoing cardiac resynchronization therapy with defibrillator (CRT-D) implantation for left ventricular systolic dysfunction (LVSD) accompanied by permanent atrial fibrillation (AF), generally, the unused atrial port is plugged at device implantation. We describe an alternative use for the atrial-port in this case report. A 43 year old gentleman with LVSD due to left ventricular non-compaction (LVNC) and AF of unknown duration underwent a CRT-D implantation after optimization of cardiac failure treatment. The atrial-port which would otherwise have been plugged was connected to a high right ventricular septal (RVS) pacing-lead and the shock-lead was positioned at the right ventricular apex (RVA). This approach permitted modified cardiac resynchronization in a high RVS to left ventricular (LV) and RVA pacing sequence using the high RVS and LV pacing combined with a shock vector including the RV apex. A standard CRT-D device with a minimum programmable A-V delay of 30 ms (technically RVS to LV delay in the 'DDD' pacing mode) was used. The device was programmed to a 'DDD' pacing mode (sequential multi-site ventricular pacing with some programmability). The mode switch operation was programmed 'OFF' since atrial sensing is unavailable. Device-delivered shocks did not cardiovert the patient back to sinus rhythm suggesting that the AF was permanent (no prior cardioversion attempts were made on the presumption that the chances of maintaining sinus rhythm, given the underlying cardiac condition, were low). Subsequently, the patient required radio-frequency ablation of the atrio-ventricular node for conducted AF. Symptomatic, echocardiographic and radiological improvement preceded atrio-ventricular node ablation.
CONCLUSION: Amongst AF patients with permanent AF undergoing CRT-D implantation, those patients who are likely to have the CRT-D device atrial-ports plugged could benefit from having both the options of (i) a RVA shock vector as well as (ii) a high RVS-pacing feasible, by utilizing the atrial-port of a conventional CRTD device for a RVS pacing lead, should a RVA shock-lead position be preferred. New device programming algorithms will be necessary to make patient-customized programming in this lead configuration flexible, more useful clinically and easy.

Entities:  

Keywords:  Atrial fibrillation (AF); Atrio-ventricular node (A-VN); Cardiac resynchronization therapy with defibrillator (CRT-D); High right ventricular septum (high RVS); Left ventricle (LV); Left ventricular non-compaction (LVNC); Left ventricular systolic dysfunction (LVSD); Radio-frequency ablation (RFA); Right ventricular apex (RVA)

Year:  2013        PMID: 24174862      PMCID: PMC3809458          DOI: 10.1016/j.jsha.2013.01.003

Source DB:  PubMed          Journal:  J Saudi Heart Assoc        ISSN: 1016-7315


  3 in total

1.  Cardiac resynchronization therapy: a meta-analysis of randomized controlled trials.

Authors:  George Wells; Ratika Parkash; Jeffrey S Healey; Mario Talajic; J Malcolm Arnold; Shannon Sullivan; Joan Peterson; Elizabeth Yetisir; Patricia Theoret-Patrick; Marilynn Luce; Anthony S L Tang
Journal:  CMAJ       Date:  2011-01-31       Impact factor: 8.262

2.  Long-term effects of cardiac resynchronisation therapy in patients with atrial fibrillation.

Authors:  K Khadjooi; P W Foley; S Chalil; J Anthony; R E A Smith; M P Frenneaux; F Leyva
Journal:  Heart       Date:  2008-01-20       Impact factor: 5.994

Review 3.  Doppler echocardiography and myocardial dyssynchrony: a practical update of old and new ultrasound technologies.

Authors:  Maurizio Galderisi; Fabio Cattaneo; Sergio Mondillo
Journal:  Cardiovasc Ultrasound       Date:  2007-09-06       Impact factor: 2.062

  3 in total
  1 in total

1.  Response to "anatomic twist to a straightforward ablation".

Authors:  David Chase; A Devi; Bobby John
Journal:  Indian Pacing Electrophysiol J       Date:  2013-11-15
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.