Literature DB >> 24173251

Effect of replacing a component of a self-etch adhesive by chlorhexidine on bonding to dentin.

César Pomacóndor-Hernández1, Alberto Nogueira de Gama Antunes, Vinicius di Hipólito, Mário Fernando de Goes.   

Abstract

The purpose of this study was to evaluate the effect of replacing a component of the self-etch adhesive Adper Scotchbond SE (liquid A + liquid B) by 2% chlorhexidine (CHX) on bond strength to dentin after 1 day, 3 months or 6 months of water storage. Eight human teeth were sectioned to expose a flat dentin surface and were then randomly assigned to 2 groups. In the control group, the dentin surfaces were treated with the adhesive according to the manufacturer's instructions. In the experimental group, liquid A was replaced by 2% CHX. Next, a 6-mm-high resin composite block was incrementally built on the bonded surfaces. The restored teeth were then sectioned to produce stick-shaped specimens (cross-sectional area - 0.8 mm2). The microtensile bond strength (µTBS) was recorded, and the failure modes were assessed. Data were analyzed by two-way repeated measures ANOVA (α=0.05). Four additional teeth were processed in order to conduct a micromorphological analysis of the resin-dentin interface. The µTBS values did not significantly decrease after water storage in either the control or the experimental group, whose values did not differ significantly irrespective of storage time. The morphological aspect of the bonding interface appears not to have been affected by CHX. A higher incidence of cohesive failures within the adhesive and mixed failures (cohesive within adhesive and resin composite) was observed for both groups. It may be concluded that dentin pre-treatment with 2% CHX did not influence significantly the bonding performance of the evaluated adhesive.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24173251     DOI: 10.1590/0103-6440201302245

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  3 in total

Review 1.  Should local drug delivery systems be used in dentistry?

Authors:  Joana Vieira Costa; Jaime Portugal; Cristina Bettencourt Neves; Ana F Bettencourt
Journal:  Drug Deliv Transl Res       Date:  2021-09-20       Impact factor: 4.617

2.  Effects of solvent volatilization time on the bond strength of etch-and-rinse adhesive to dentin using conventional or deproteinization bonding techniques.

Authors:  José Aginaldo de Sousa Júnior; Márcia Luciana Carregosa Santana; Fabricio Eneas Diniz de Figueiredo; André Luis Faria-E-Silva
Journal:  Restor Dent Endod       Date:  2015-03-17

Review 3.  MMP Inhibitors and Dentin Bonding: Systematic Review and Meta-Analysis.

Authors:  O Kiuru; J Sinervo; H Vähänikkilä; V Anttonen; L Tjäderhane
Journal:  Int J Dent       Date:  2021-05-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.