Literature DB >> 24171553

A differentially pumped dual linear quadrupole ion trap (DLQIT) mass spectrometer: a mass spectrometer capable of MS(n) experiments free from interfering reactions.

Benjamin C Owen1, Tiffany M Jarrell, Jae C Schwartz, Rob Oglesbee, Mark Carlsen, Enada F Archibold, Hilkka I Kenttämaa.   

Abstract

A novel differentially pumped dual linear quadrupole ion trap (DLQIT) mass spectrometer was designed and built to facilitate tandem MS experiments free from interfering reactions. The instrument consists of two differentially pumped Thermo Scientific linear quadrupole ion trap (LQIT) systems that have been connected via an ion transfer octupole encased in a machined manifold. Tandem MS experiments can be performed in the front trap and then the resulting product ions can be transferred via axial ejection into the back trap for further, independent tandem MS experiments in a differentially pumped area. This approach allows the examination of consecutive collision-activated dissociation (CAD) and ion-molecule reactions without unwanted side reactions that often occur when CAD and ion-molecule reactions are examined in the same space. Hence, it greatly facilitates investigations of ion structures. In addition, the overall lower pressure of the DLQIT, as compared to commercial LQIT instruments, results in a reduction of unwanted side reactions with atmospheric contaminants, such as water and oxygen, in CAD and ion-molecule experiments.

Entities:  

Mesh:

Year:  2013        PMID: 24171553     DOI: 10.1021/ac401956f

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Polar Effects Control the Gas-phase Reactivity of Charged para-Benzyne Analogs.

Authors:  Ashley M Wittrig; Enada F Archibold; Huaming Sheng; John J Nash; Hilkka I Kenttämaa
Journal:  Int J Mass Spectrom       Date:  2015-02-01       Impact factor: 1.986

2.  Substituent Effects on the Reactivity of the 2,4,6-Tridehydropyridinium Cation, an Aromatic σ,σ,σ-Triradical.

Authors:  Jinshan Gao; Bartłomiej J Jankiewicz; Huaming Sheng; Lindsey Kirkpatrick; Xin Ma; John J Nash; Hilkka I Kenttämaa
Journal:  European J Org Chem       Date:  2018-11-15

Review 3.  Towards Higher Sensitivity of Mass Spectrometry: A Perspective From the Mass Analyzers.

Authors:  Chang Li; Shiying Chu; Siyuan Tan; Xinchi Yin; You Jiang; Xinhua Dai; Xiaoyun Gong; Xiang Fang; Di Tian
Journal:  Front Chem       Date:  2021-12-21       Impact factor: 5.221

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.