Literature DB >> 24169248

[Comparison of the efficacy of different types of laryngeal mask airways in patients undergoing laparoscopic gynecological surgery].

Ying-bin Shi1, Ming-zhang Zuo, Xiang-hua Du, Zhen Yu.   

Abstract

OBJECTIVE: To compare the efficacy of laryngeal mask airway Supreme, ProSeal and I-gel in patients undergoing laparoscopic gynecological surgery.
METHODS: From Jan 2010 to Sep 2012 in Beijing Hospital, approved by hospital ethics committee, ninety ASA IorII patients, aged 21-64 yr, weighing 45-90 kg, undergoing laparoscopic gynecological surgery, were randomized into 3 groups (n = 30 each): LMA Supreme group (group S), LMA ProSeal group (group P)and LMA I-gel group (group I). Mallampatti test was performed before operation for each case. Anesthesia was induced with target-controlled infusion. After the patients lost consciousness, rocuronium 0.6 mg/kg was given to facilitate the LMA insertion. LMA Supreme, LMA ProSeal and LMA I-gel were inserted in S, P and I groups respectively. A gastric tube was inserted through the drain tube of the LMA. The LMA placement time, the number of attempts of LMA insertion, the number of attempts of gastric tube placement, the airway sealing pressure, the parameters of ventilation, and complications (sore throat, odynophagia, hoarseness, regurgitation of gastric contents, LMA with adhesion of blood)were recorded. The fiberoptic laryngoscopy scores were assessed after LMA placement. The anesthesia time and recovery time were also recorded.
RESULTS: There was no significant difference in the anesthesia time, recovery time, fiberoptic bronchoscopy scores among the three groups (P > 0.05). Parameters of ventilation in each group were normal. The success rates of LMA and gastric tube placement were 100% in each group. The airway sealing pressure in S, P and I groups were 25 ± 5 cm H2O, 32 ± 5 cm H2O, 30 ± 6 cm H2O respectively, the airway sealing pressure was significantly higher in group P and group I, compare with group S (P < 0.05). The LMA placement time in S, P and I groups were 8 ± 4s, 10 ± 5s, 8 ± 3s respectively, while the incidence of sore throat were 17%, 20%, 3%. The LMA placement time was significantly shorter and the incidence of sore throat was significantly lower in group I than in group P (P < 0.05).
CONCLUSIONS: The three LMA can all be used effectively for gynecological laparoscopic surgery. LMA I-gel and LMA ProSeal can provide higher airway sealing pressure. LMA I-gel provides adequate ventilation during operation with fewer complications.

Entities:  

Mesh:

Year:  2013        PMID: 24169248

Source DB:  PubMed          Journal:  Zhonghua Yi Xue Za Zhi        ISSN: 0376-2491


  6 in total

Review 1.  Role of laryngeal mask airway in laparoscopic cholecystectomy.

Authors:  José M Beleña; Ernesto Josué Ochoa; Mónica Núñez; Carlos Gilsanz; Alfonso Vidal
Journal:  World J Gastrointest Surg       Date:  2015-11-27

Review 2.  Comparison of the i-gel and the laryngeal mask airway proseal during general anesthesia: a systematic review and meta-analysis.

Authors:  Sun Kyung Park; Geun Joo Choi; Yun Suk Choi; Eun Jin Ahn; Hyun Kang
Journal:  PLoS One       Date:  2015-03-26       Impact factor: 3.240

3.  Comparison of I-gel for general anesthesia in obese and nonobese patients.

Authors:  Rati Prabha; Rajesh Raman; Mohammad Parvez Khan; Dinesh Kaushal; Ahsan Khaliq Siddiqui; Haider Abbas
Journal:  Saudi J Anaesth       Date:  2018 Oct-Dec

4.  Comparison of Two Supraglottic Airway Devices: I-gel Airway and ProSeal Laryngeal Mask Airway Following Digital Insertion in Nonparalyzed Anesthetized Patients.

Authors:  Ankur Luthra; Rajeev Chauhan; Amit Jain; Ishwar Bhukal; Shalvi Mahajan; Indu Bala
Journal:  Anesth Essays Res       Date:  2019-12-16

5.  An Analysis of the Comparative Efficacy Between a Third-Generation and a Second-Generation Supraglottic Airway Device in Patients Undergoing Laparoscopic Cholecystectomy.

Authors:  Darvish Hussain; Raksha Kundal; Anil Kumar; Nikki Sabharwal
Journal:  Cureus       Date:  2022-02-25

Review 6.  Comparison of oropharyngeal leak pressure and clinical performance of LMA ProSeal™ and i-gel® in adults: Meta-analysis and systematic review.

Authors:  Hye Won Shin; Hae Na Yoo; Go Eun Bae; Jun Chul Chang; Min Kyung Park; Hae Seun You; Hyun Jung Kim; Hyung Sik Ahn
Journal:  J Int Med Res       Date:  2016-03-23       Impact factor: 1.671

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.