Literature DB >> 24163640

Continuous Time Level Crossing Sampling ADC for Bio-Potential Recording Systems.

Wei Tang1, Ahmad Osman, Dongsoo Kim, Brian Goldstein, Chenxi Huang, Berin Martini, Vincent A Pieribone, Eugenio Culurciello.   

Abstract

In this paper we present a fixed window level crossing sampling analog to digital convertor for bio-potential recording sensors. This is the first proposed and fully implemented fixed window level crossing ADC without local DACs and clocks. The circuit is designed to reduce data size, power, and silicon area in future wireless neurophysiological sensor systems. We built a testing system to measure bio-potential signals and used it to evaluate the performance of the circuit. The bio-potential amplifier offers a gain of 53 dB within a bandwidth of 200 Hz-20 kHz. The input-referred rms noise is 2.8 µV. In the asynchronous level crossing ADC, the minimum delta resolution is 4 mV. The input signal frequency of the ADC is up to 5 kHz. The system was fabricated using the AMI 0.5 µm CMOS process. The chip size is 1.5 mm by 1.5 mm. The power consumption of the 4-channel system from a 3.3 V supply is 118.8 µW in the static state and 501.6 µW with a 240 kS/s sampling rate. The conversion efficiency is 1.6 nJ/conversion.

Entities:  

Keywords:  Analog to digital conversion (ADC); asynchronous delta modulation (ADM); bio-potential recording applications; clock-less operation; continuous time level crossing sampling; fixed window method; large-scale sensor array

Year:  2013        PMID: 24163640      PMCID: PMC3806520          DOI: 10.1109/TCSI.2012.2220464

Source DB:  PubMed          Journal:  IEEE Trans Circuits Syst I Regul Pap        ISSN: 1549-8328            Impact factor:   3.605


  5 in total

1.  A low-power asynchronous ECG acquisition system in CMOS technology.

Authors:  Sungkil Hwang; Michael Trakimas; Sameer Sonkusale
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

2.  A bio-amplifier with pulse output.

Authors:  Du Chen; John G Harris; Jose C Principe
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

3.  A VLSI Neural Monitoring System With Ultra-Wideband Telemetry for Awake Behaving Subjects.

Authors:  E Greenwald; M Mollazadeh; C Hu; E Culurciello; V Thakor
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2011-04       Impact factor: 3.833

4.  Listening to Brain Microcircuits for Interfacing With External World-Progress in Wireless Implantable Microelectronic Neuroengineering Devices: Experimental systems are described for electrical recording in the brain using multiple microelectrodes and short range implantable or wearable broadcasting units.

Authors:  Arto V Nurmikko; John P Donoghue; Leigh R Hochberg; William R Patterson; Yoon-Kyu Song; Christopher W Bull; David A Borton; Farah Laiwalla; Sunmee Park; Yin Ming; Juan Aceros
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2010       Impact factor: 10.961

5.  HermesC: low-power wireless neural recording system for freely moving primates.

Authors:  Cynthia A Chestek; Vikash Gilja; Paul Nuyujukian; Ryan J Kier; Florian Solzbacher; Stephen I Ryu; Reid R Harrison; Krishna V Shenoy
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2009-06-02       Impact factor: 3.802

  5 in total
  2 in total

1.  Event-Driven ECG Sensor in Healthcare Devices for Data Transfer Optimization.

Authors:  Manel Ben-Romdhane; Asma Maalej; Mariam Tlili; Chiheb Rebai; François Rivet; Dominique Dallet
Journal:  Arab J Sci Eng       Date:  2020-03-31       Impact factor: 2.334

2.  An electronic neuromorphic system for real-time detection of high frequency oscillations (HFO) in intracranial EEG.

Authors:  Mohammadali Sharifshazileh; Karla Burelo; Johannes Sarnthein; Giacomo Indiveri
Journal:  Nat Commun       Date:  2021-05-25       Impact factor: 14.919

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.