Literature DB >> 24162895

Myopia screening: combining visual acuity and noncycloplegic autorefraction.

Yingyan Ma1, Xiangui He, Haidong Zou, Lina Lu, Xiaomei Qu, Jianfeng Zhu.   

Abstract

PURPOSE: To explore the effectiveness of combining uncorrected visual acuity (UCVA) and noncycloplegic autorefraction (NCAR) for large-scale myopia screening in schoolchildren with a high prevalence of myopia.
METHODS: A total of 1687 children aged between 6 and 12 years, from five primary schools in the Baoshan district of Shanghai participated in the study. We measured UCVA and autorefraction before and after cycloplegia by a Topcon KR-8800. We drew receiver operating characteristic curves to achieve the best cutoff points and their corresponding sensitivities and specificities for the UCVA and NCAR, respectively. We then combined the UCVA and NCAR in serial order to explore the optimal criterion and its effectiveness. A specificity of 90% was set to compare the sensitivities among the three tests. The children were divided into three age groups (aged 6 to 7, 8 to 10, 11 to 12 years) to further examine this new method.
RESULTS: A total of 1639 children with an average age of 9.35 (SD, 1.6) years were finally included, among which 428 (26.11%) children were diagnosed as being myopic (spherical equivalent refraction (SER) less than or equal to -0.5 diopters [D]). For the UCVA, the cutoff point is 0.2 logarithm of the minimum angle of resolution (20/32), with a sensitivity and specificity of 63.6% and 94.0%, respectively. For NCAR, the cutoff point is SER less than or equal to -0.75 D, with a sensitivity and specificity of 88.6% and 86.1%, respectively. When UCVA is combined with NCAR, the best cutoff point is UCVA less than or equal to 0 logarithm of the minimum angle of resolution (20/20) and SER less than or equal to -0.75 D, with a sensitivity and specificity of 84.4% and 90.5%, respectively. At a specificity of 90%, the sensitivities are 63.55%, 78.50%, and 84.35%, respectively, for UCVA, NCAR, and the combination test. In all age groups, the combination test had the highest sensitivities among the three tests.
CONCLUSIONS: In a population with a high prevalence of myopia, combining the UCVA and NCAR in serial order achieved higher sensitivity than either of the two tests alone, when specificity was set at 90%.

Entities:  

Mesh:

Year:  2013        PMID: 24162895     DOI: 10.1097/OPX.0000000000000095

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  9 in total

1.  Proportion and characteristic of emmetropia in schoolchildren aged 6-11y: the Shenzhen elementary school eye study.

Authors:  Xian-Ming Jiang; Ying-Ying Lu; Xiao Han; Qian Tan; Jun-Shu Wu
Journal:  Int J Ophthalmol       Date:  2020-12-18       Impact factor: 1.779

2.  Axial length/corneal radius ratio: association with refractive state and role on myopia detection combined with visual acuity in Chinese schoolchildren.

Authors:  Xiangui He; Haidong Zou; Lina Lu; Rong Zhao; Huijuan Zhao; Qiangqiang Li; Jianfeng Zhu
Journal:  PLoS One       Date:  2015-02-18       Impact factor: 3.240

3.  Screening for significant refractive error using a combination of distance visual acuity and near visual acuity.

Authors:  Peiyao Jin; Jianfeng Zhu; Haidong Zou; Lina Lu; Huijuan Zhao; Qiangqiang Li; Xiangui He
Journal:  PLoS One       Date:  2015-02-17       Impact factor: 3.240

4.  Corneal Thickness Profile and Associations in Chinese Children Aged 7 to 15 Years Old.

Authors:  Yingyan Ma; Xiaofeng Zhu; Xiangui He; Lina Lu; Jianfeng Zhu; Haidong Zou
Journal:  PLoS One       Date:  2016-01-11       Impact factor: 3.240

5.  Cohort study with 4-year follow-up of myopia and refractive parameters in primary schoolchildren in Baoshan District, Shanghai.

Authors:  Yingyan Ma; Haidong Zou; Senlin Lin; Xun Xu; Rong Zhao; Lina Lu; Huijuan Zhao; Qiangqiang Li; Ling Wang; Jianfeng Zhu; Xiangui He
Journal:  Clin Exp Ophthalmol       Date:  2018-04-16       Impact factor: 4.207

6.  Effect of cycloplegia on the measurement of refractive error in Chinese children.

Authors:  Tao Li; Xiaodong Zhou; Jie Zhu; Xiaojing Tang; Xiaoyan Gu
Journal:  Clin Exp Optom       Date:  2018-08-22       Impact factor: 2.742

7.  Comparison of noncycloplegic and cycloplegic autorefraction in categorizing refractive error data in children.

Authors:  Padmaja Sankaridurg; Xiangui He; Thomas Naduvilath; Minzhi Lv; Arthur Ho; Earl Smith; Paul Erickson; Jianfeng Zhu; Haidong Zou; Xun Xu
Journal:  Acta Ophthalmol       Date:  2017-11       Impact factor: 3.761

8.  Automatic identification of myopia based on ocular appearance images using deep learning.

Authors:  Yahan Yang; Ruiyang Li; Duoru Lin; Xiayin Zhang; Wangting Li; Jinghui Wang; Chong Guo; Jianyin Li; Chuan Chen; Yi Zhu; Lanqin Zhao; Haotian Lin
Journal:  Ann Transl Med       Date:  2020-06

9.  Design and methodology of the Shanghai child and adolescent large-scale eye study (SCALE).

Authors:  Xiangui He; Rong Zhao; Padmaja Sankaridurg; Jianfeng Zhu; Thomas Naduvilath; Yingyan Ma; Lina Lu; Minzhi Lv; Earl L Smith; Serge Resnikoff; Kovin Naidoo; Haidong Zou; Xun Xu
Journal:  Clin Exp Ophthalmol       Date:  2017-10-27       Impact factor: 4.207

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.