Literature DB >> 24161791

Pelvic periprosthetic bone mineral density measurement around cemented vs cementless acetabular prostheses.

Raveen L Jayasuriya1, J Mark Wilkinson2.   

Abstract

We compared the short-term precision of pelvic periprosthetic bone mineral density (BMD) measurement around a cementless acetabular prosthesis (n = 29) vs a cemented all-polyethylene acetabular prosthesis (n = 19) in patients after total hip arthroplasty. Two dual-energy x-ray absorptiometry scans of the pelvis were made on the same day in each subject with subject repositioning between scans and analyzed independently with a 4-region of interest model. Precision was expressed as coefficient of variation (CV%). The measured BMD around the cemented prostheses was greater than the cementless prostheses p < 0.004, all analyses). The net CV for pelvic BMD measurements around the cementless prosthesis was 1.9% vs 3.6% around the cemented prosthesis (F-test p < 0.001). The CVs of individual regions of interest was between 2.8% and 4.8% for the cementless prosthesis vs 4.4% to 8.4% for the cemented prosthesis (F-test; p < 0.05, all comparisons). Prospective studies would require 57 subjects to detect a 10% change in net pelvic BMD around a cementless prosthesis and 122 to detect a similar change around a cemented prosthesis with 90% power and with an alpha error of 0.05. In conclusion, the precision of pelvic BMD measurements made around cementless prostheses are better vs those for cemented prostheses. Dual-energy x-ray absorptiometry studies of cemented prosthesis require approximately double the number of subjects vs cementless prostheses to achieve a similar level of power.
Copyright © 2014 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  BMD; DXA; pelvis; precision; total hip arthroplasty

Mesh:

Substances:

Year:  2013        PMID: 24161791     DOI: 10.1016/j.jocd.2013.09.005

Source DB:  PubMed          Journal:  J Clin Densitom        ISSN: 1094-6950            Impact factor:   2.617


  2 in total

1.  Inferior stabilization of cementless compared with cemented dual-mobility cups in elderly osteoarthrosis patients: a randomized controlled radiostereometry study on 60 patients with 2 years' follow-up.

Authors:  Steffan Tabori-Jensen; Sebastian Breddam Mosegaard; Torben B Hansen; Maiken Stilling
Journal:  Acta Orthop       Date:  2020-02-06       Impact factor: 3.717

2.  Radiographic evaluation of early periprosthetic acetabular bone contrast and prosthetic head acetabular coverage after uncemented and cemented total hip prosthesis in dogs.

Authors:  Ayman A Mostafa; Karin Lucas; Ingo Nolte; Patrick Wefstaedt
Journal:  BMC Vet Res       Date:  2016-12-03       Impact factor: 2.741

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.