INTRODUCTION: Ambulatory oxygen (O2) is prescribed to interstitial lung disease (ILD) patients with mild hypoxemia, breathlessness and dyspnea on exertion. Oxygen titration is generally done with the 6 minute walk test (6MWT) to determine the O2 flow preventing oxygen saturation by pulse oximetry (SpO2) from falling below 88%. His study was designed to generate a 6MWT index predicting the O2 flow allowing completion of the 6MWT without oxygen desaturation. METHODS: Oxygen titration data from a group of 66 ILD patients and 30 controls, were used to generate the algorithm determining an index (O2-GAP) predicting oxygen flow required to complete a 6MWT without desaturation below 88%. This index was validated in a group of 93 ILD patients. RESULTS: The O2-GAP index, as obtained from the derivation population, (r(2) = 0.97, p < 0.001) was shown to correctly predict the oxygen flow required to complete the 6MWT without SpO2 falling below 88% validated in the validation population (r(2) = 0.842; p < 0.001). CONCLUSIONS: The O2-GAP index appears to be a useful tool to titrate ambulatory O2 with a single 6MWT on room air in ILD patients with breathlessness and dyspnea on exertion.
INTRODUCTION: Ambulatory oxygen (O2) is prescribed to interstitial lung disease (ILD) patients with mild hypoxemia, breathlessness and dyspnea on exertion. Oxygen titration is generally done with the 6 minute walk test (6MWT) to determine the O2 flow preventing oxygen saturation by pulse oximetry (SpO2) from falling below 88%. His study was designed to generate a 6MWT index predicting the O2 flow allowing completion of the 6MWT without oxygen desaturation. METHODS:Oxygen titration data from a group of 66 ILDpatients and 30 controls, were used to generate the algorithm determining an index (O2-GAP) predicting oxygen flow required to complete a 6MWT without desaturation below 88%. This index was validated in a group of 93 ILDpatients. RESULTS: The O2-GAP index, as obtained from the derivation population, (r(2) = 0.97, p < 0.001) was shown to correctly predict the oxygen flow required to complete the 6MWT without SpO2 falling below 88% validated in the validation population (r(2) = 0.842; p < 0.001). CONCLUSIONS: The O2-GAP index appears to be a useful tool to titrate ambulatory O2 with a single 6MWT on room air in ILDpatients with breathlessness and dyspnea on exertion.
Authors: Marko Topalovic; Vasileios Exadaktylos; Marc Decramer; Thierry Troosters; Daniel Berckmans; Wim Janssens Journal: Med Biol Eng Comput Date: 2014-09-30 Impact factor: 2.602
Authors: Gian Marco Manzetti; Karishma Hosein; Matthew J Cecchini; Keith Kwan; Mohamed Abdelrazek; Maurizio Zompatori; Paola Rogliani; Marco Mura Journal: BMC Pulm Med Date: 2021-12-04 Impact factor: 3.317