Literature DB >> 24156592

Flexor pulley reconstruction after rupture following corticosteroid injections for trigger thumb: a case report.

Michio Kimura1, Nagatsugu Kuroshima, Takashi Matsushita.   

Abstract

We report a rare case of limitation of active flexion and subcutaneous bow-stringing as a result of flexor pulley rupture after repeated corticosteroid injections for trigger thumb. Complete rupture of the A1 and oblique flexor pulleys was confirmed during surgery, and the pulley system was reconstructed with a "three-loop technique" using a free palmaris longus autograft. This technique provided enough strength to allow early mobilization and prompt recovery to full range of motion.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24156592     DOI: 10.1142/S0218810413720301

Source DB:  PubMed          Journal:  Hand Surg        ISSN: 0218-8104


  1 in total

1.  Subclinical Partial Attritional Rupture of the Flexor Digitorum Profundus as an Etiology of Atraumatic Trigger Finger.

Authors:  D Anthony Bastian; Nicholas Kusnezov; John C Dunn; Justin S Mitchell; Miguel Pirela-Cruz
Journal:  Case Rep Orthop       Date:  2017-07-12