Literature DB >> 24155598

Evaluation of Physical Properties of Tissue Conditioning Materials as used in Functional Impression - A Lab Study.

Kumar B S Shylesh1, R B Hallikerimath, V V Rajeev, S Ganesh, S Meenakshi.   

Abstract

BACKGROUND: The purpose of this study was to identify the basic physical properties of 3 commonly available tissue-conditioning materials to gain knowledge for their clinical use as impression materials. MATERIALS &
METHODS: A total of 60 samples were prepared and each sample was mixed and prepared according to manufacture direction. Finally five specimens of each tissue conditioners were subjected for each of the above test at different time duration. RESULTS &
CONCLUSION: The study showed that all the materials underwent water loss from the time of mixing to 24 hr & became hard. The plasticity of coecomfort & viscogel decreased from the time of mixing upto 1hr & 2hr respectively & again increased after that till 24 hrs, but the softone showed decreased plasticity after 30 min till 24hrs. Softone & coecomfort at 30 min showed better flow & more plasticity than that of viscogel. The dimensional accuracy of softone & viscogel at 30min is better than that of coecomfort. Thus softone at 30 min after mixing has better Dimensional accuracy, Plasticity and Flow; suitable for making functional impression then that of Coe-comfort and Viscogel. How to cite this article: Shylesh K B S, Hallikerimath R B, Rajeev V V, Ganesh S, Meenakshi S. Evaluation of Physical Properties of Tissue Conditioning Materials as used in Functional Impression - A Lab Study. J Int Oral Health 2013; 5(3):20-27.

Entities:  

Keywords:  Dimensional accuracy; Flow; Hardness; Plasticity; Strain under compression; Water loss

Year:  2013        PMID: 24155598      PMCID: PMC3769867     

Source DB:  PubMed          Journal:  J Int Oral Health        ISSN: 0976-1799


  7 in total

1.  Clinical implications of resilient denture lining material research. Part II: Gelation and flow properties of tissue conditioners.

Authors:  B S Graham; D W Jones; E J Sutow
Journal:  J Prosthet Dent       Date:  1991-03       Impact factor: 3.426

2.  Rheology of tissue conditioners.

Authors:  H Murata; T Hamada; E Djulaeha; H Nikawa
Journal:  J Prosthet Dent       Date:  1998-02       Impact factor: 3.426

3.  Clinical implications of resilient denture lining material research. Part I: Flexibility and elasticity.

Authors:  B S Graham; D W Jones; E J Sutow
Journal:  J Prosthet Dent       Date:  1989-10       Impact factor: 3.426

4.  Mechanical properties of tissue conditioners. Part I: theoretical considerations, behavioral characteristics, and tensile properties.

Authors:  J A McCarthy; J B Moser
Journal:  J Prosthet Dent       Date:  1978-07       Impact factor: 3.426

Review 5.  Temporary soft lining materials. A review of their uses.

Authors:  A Harrison
Journal:  Br Dent J       Date:  1981-12-15       Impact factor: 1.626

6.  Visco-elastic properties of four currently used tissue conditioners.

Authors:  B De Mot; M De Clercq; P Rousseeuw
Journal:  J Oral Rehabil       Date:  1984-09       Impact factor: 3.837

7.  Consistency and softness of soft liners.

Authors:  Z Yoeli; V Miller; C Zeltser
Journal:  J Prosthet Dent       Date:  1996-04       Impact factor: 3.426

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.