| Literature DB >> 2415546 |
N Kurosawa, S Kuribayashi, E Owada, K Ito, M Nioka, M Arakawa, R Fukuda.
Abstract
A high-performance liquid chromatographic method was developed for monitoring the serum concentration of streptomycin. The method includes clean-up using a Sep-Pak C18 cartridge and quantitation using dihydrostreptomycin as an internal standard. Streptomycin and dihydrostreptomycin were separated by reversed-phase ion-pair chromatography on LiChrosorb RP-18 and detected by UV absorption (195 nm). The calibration graph of serum streptomycin concentration was linear over the range 5-50 micrograms/ml. Streptomycin was added to serum at the level of 20.0 micrograms/ml and its concentration was determined to be 18.9 micrograms/ml with a coefficient of variation of 2.07% (n = 5). The clinical application of this method was confirmed by comparison with fluorescence polarization immunoassay.Entities:
Mesh:
Substances:
Year: 1985 PMID: 2415546 DOI: 10.1016/s0378-4347(00)84606-x
Source DB: PubMed Journal: J Chromatogr