Literature DB >> 24154924

A micro-liter viscosity and density sensor for the rheological characterization of DNA solutions in the kilo-hertz range.

Philipp Rust1, Damiano Cereghetti, Jurg Dual.   

Abstract

When measuring the properties of fluids from biological sources, sample volumes in the micro-liter range are often desired as higher volumes may not be available or are very expensive. Miniaturized viscosity and density sensors based on a vibrating cantilever fulfill this requirement. In this paper, the possibility of measuring viscosity and density of DNA solutions at the same time using such a sensor is shown. The sensor requires a sample volume of 10 μl. By doing a titration of a solution containing 110 bp long strands of DNA in the diluted, Newtonian regime, the intrinsic viscosity can be determined to be 0.047 ml mg(-1) using the cantilever sensor. The cantilever is also tested with solutions of 10 kbp long strands with concentrations in the semi-dilute, non-Newtonian regime. The comparably small change in resonance frequency and damping observed using these solutions at 12.5 kHz is attributed to shear thinning, which is expected when extrapolating results from other groups.

Mesh:

Substances:

Year:  2013        PMID: 24154924     DOI: 10.1039/c3lc50857a

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  4 in total

1.  Highly sensitive measurement of liquid density in air using suspended microcapillary resonators.

Authors:  Oscar Malvar; Daniel Ramos; Carmen Martínez; Priscila Kosaka; Javier Tamayo; Montserrat Calleja
Journal:  Sensors (Basel)       Date:  2015-03-30       Impact factor: 3.576

2.  A rapid and practical technique for real-time monitoring of biomolecular interactions using mechanical responses of macromolecules.

Authors:  Mehmet C Tarhan; Nicolas Lafitte; Yannick Tauran; Laurent Jalabert; Momoko Kumemura; Grégoire Perret; Beomjoon Kim; Anthony W Coleman; Hiroyuki Fujita; Dominique Collard
Journal:  Sci Rep       Date:  2016-06-16       Impact factor: 4.379

3.  Fluorescence polarization system for rapid COVID-19 diagnosis.

Authors:  Chang Yeol Lee; Ismail Degani; Jiyong Cheong; Jae-Hyun Lee; Hyun-Jung Choi; Jinwoo Cheon; Hakho Lee
Journal:  Biosens Bioelectron       Date:  2021-01-30       Impact factor: 12.545

Review 4.  Fabricating Silicon Resonators for Analysing Biological Samples.

Authors:  Momoko Kumemura; Deniz Pekin; Vivek Anand Menon; Isabelle Van Seuningen; Dominique Collard; Mehmet Cagatay Tarhan
Journal:  Micromachines (Basel)       Date:  2021-12-12       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.