Literature DB >> 24154791

Temporal variation of the leak pressure of uncuffed endotracheal tubes following pediatric intubation: an observational study.

Shreya Patel1, Kirk Lalwani, Jeffrey Koh, Lei Wu, Rongwei Fu.   

Abstract

PURPOSE: Uncuffed endotracheal tubes are still preferred over cuffed tubes in certain situations in pediatric anesthesia. Inaccurately sized uncuffed endotracheal tubes may lead to inadequate ventilation or tracheal mucosal damage during anesthesia. Endotracheal tube size in children is usually assessed by measuring the audible leak pressure; if the fit of the tube and the leak pressure decrease significantly with time, reintubation during surgery as a result of inability to ventilate effectively may be challenging, and could lead to patient morbidity. There is no evidence to indicate whether leak pressure increases or decreases with time following endotracheal intubation with uncuffed tubes in children.
METHODS: We measured leak pressure for 30 min following tracheal intubation in 46 ASA I children age 0-7 years after excluding factors known to modify leak pressure.
RESULTS: The largest mean change in leak pressure occurred between time points 0 and 15 min, an increase of 3.5 cmH2O. Endotracheal tube size and type of procedure were associated with the leak pressure. In the final linear mixed model, there were no statistically significant variations in leak pressure over time (P = 0.129) in this group of children.
CONCLUSIONS: We did not identify a consistent change in leak pressure within 30 min following tracheal intubation with uncuffed endotracheal tubes in this group of children.

Entities:  

Mesh:

Year:  2013        PMID: 24154791     DOI: 10.1007/s00540-013-1728-z

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  7 in total

1.  Decreased incidence of subglottic stenosis using an "appropriate-sized" endotracheal tube in neonates.

Authors:  J M Sherman; H Nelson
Journal:  Pediatr Pulmonol       Date:  1989

2.  Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs.

Authors:  R D Seegobin; G L van Hasselt
Journal:  Br Med J (Clin Res Ed)       Date:  1984-03-31

3.  Laryngeal damage from tracheal intubation.

Authors:  J Holzki
Journal:  Paediatr Anaesth       Date:  1997       Impact factor: 2.556

4.  Optimally fitted tracheal tubes decrease the probability of postextubation adverse events in children undergoing general anesthesia.

Authors:  Pertti Suominen; Tomi Taivainen; Netta Tuominen; Ville Voipio; Kari Wirtavuori; Arja Hiller; Reijo Korpela; Tiina Karjalainen; Olli Meretoja
Journal:  Paediatr Anaesth       Date:  2006-06       Impact factor: 2.556

5.  Prospective randomized controlled multi-centre trial of cuffed or uncuffed endotracheal tubes in small children.

Authors:  M Weiss; A Dullenkopf; J E Fischer; C Keller; A C Gerber
Journal:  Br J Anaesth       Date:  2009-11-03       Impact factor: 9.166

Review 6.  The future of the cuffed endotracheal tube.

Authors:  Gavin F Fine; Lawrence M Borland
Journal:  Paediatr Anaesth       Date:  2004-01       Impact factor: 2.556

7.  Factors affecting leak around tracheal tubes in children.

Authors:  D A Finholt; D B Henry; R C Raphaely
Journal:  Can Anaesth Soc J       Date:  1985-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.