Literature DB >> 24152115

First comparative evaluation of a new leukapheresis technology in non-cytokine-stimulated donors.

P A Steininger1, E F Strasser, D Weiss, S Achenbach, R Zimmermann, R Eckstein.   

Abstract

BACKGROUND AND OBJECTIVES: Leukapheresis is an important source for mononuclear cells (MNCs) used in adoptive immunotherapies. Differences in the apheresis technology concerning physical conditions during cell separation and the optical detection system can affect the product's cellular content.
MATERIALS AND METHODS: In a paired analysis, twenty healthy non-cytokine-stimulated donors underwent MNC collection at the Spectra Optia (Terumo BCT, Lakewood, CO, USA) and the COM.TEC (Fresenius Kabi, Bad Homburg, Germany) device. In twelve donors, apheresis was additionally performed with the Amicus (Fenwal Inc., Lake Zurich, IL, USA). Donor response to leukapheresis and product composition was compared.
RESULTS: Mean yields of CD14+ (CD3+) cells were 1·64±0·70x10(9) (2·36±0·96×10(9)) in the Spectra Optia, 1·45±0·50×10(9) (3·03±1·04×10(9)) in the COM.TEC and 1·20±0·37×10(9) (2·80±1·00×10(9)) in the Amicus products, respectively. The Spectra Optia collected significantly more CD14+ monocytes than the Amicus and significantly less CD3+ T cells than the COM.TEC (P=0·002 and P=0·021). Apheresis products of the Spectra Optia showed the significantly lowest red blood cell yields while the Amicus generated products with the significantly lowest platelet contents.
CONCLUSIONS: Leukaphereses with the three devices resulted in almost equal total MNC yields. MNC products of the Spectra Optia and the Amicus could be used in preference for the monocyte enrichment by the Elutra system and the leukapheresis procedures could be also favourably applied in patients with low platelet counts. The COM.TEC is more efficient in monocyte and T-cell collection with the disadvantage of high residual non-target cell content in the products.
© 2013 International Society of Blood Transfusion.

Entities:  

Keywords:  apheresis technology; cell therapy; collection efficiency; mononuclear cell apheresis

Mesh:

Substances:

Year:  2013        PMID: 24152115     DOI: 10.1111/vox.12102

Source DB:  PubMed          Journal:  Vox Sang        ISSN: 0042-9007            Impact factor:   2.144


  5 in total

1.  Low-Volume Leukapheresis in Non-Cytokine-Stimulated Donors for the Collection of Mononuclear Cells.

Authors:  Adamma Anyanwu; Nicole Sitzmann; Svetlana Hetjens; Harald Klüter; Patrick Wuchter
Journal:  Transfus Med Hemother       Date:  2018-08-28       Impact factor: 3.747

Review 2.  Genetic Engineering and Manufacturing of Hematopoietic Stem Cells.

Authors:  Xiuyan Wang; Isabelle Rivière
Journal:  Mol Ther Methods Clin Dev       Date:  2017-03-18       Impact factor: 6.698

3.  Erythrocyte depletion from bone marrow: performance evaluation after 50 clinical-scale depletions with Spectra Optia BMC.

Authors:  Soo-Zin Kim-Wanner; Gesine Bug; Juliane Steinmann; Salem Ajib; Nadine Sorg; Carolin Poppe; Milica Bunos; Eva Wingenfeld; Christiane Hümmer; Beate Luxembourg; Erhard Seifried; Halvard Bonig
Journal:  J Transl Med       Date:  2017-08-11       Impact factor: 5.531

Review 4.  Optimizing peripheral blood stem cells transplantation outcome through amend relapse and graft failure: a review of current literature.

Authors:  Saeed Mohammadi; Amir Hossein Norooznezhad; Ashraf Malek Mohammadi; Hajar Nasiri; Mohsen Nikbakht; Najmaldin Saki; Mohammad Vaezi; Kamran Alimoghaddam; Ardeshir Ghavamzadeh
Journal:  Exp Hematol Oncol       Date:  2017-08-09

5.  GMP-production of purified human B lymphocytes for the adoptive transfer in patients after allogeneic hematopoietic stem cell transplantation.

Authors:  Hannes Tittlbach; Andrea Schneider; Julian Strobel; Robert Zimmermann; Stefanie Maas; Bernd Gebhardt; Georg Rauser; Michael Mach; Andreas Mackensen; Thomas H Winkler; Julia Winkler
Journal:  J Transl Med       Date:  2017-11-07       Impact factor: 5.531

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.