Literature DB >> 24151756

Incidence and impact of prosthesis-patient mismatch after transcatheter aortic valve implantation.

Sabine Bleiziffer1, Ina Hettich, Andrea Hutter, Anke Wagner, Marcus-André Deutsch, Nicolo Piazza, Rüdiger Lange.   

Abstract

BACKGROUND AND AIM OF THE STUDY: The study aim was to investigate the incidence of patient-prosthesis mismatch (PPM) with new catheter valves, and its influence on the patients' clinical state. At present, few echocardiographic data are available on the incidence and impact of PPM with the CoreValve and Sapien prostheses for transcatheter aortic valve implantation (TAVI).
METHODS: The reliability of effective orifice area (EOA) measurements was assured by awaiting an interval of six months after TAVI. Of 256 survivors after TAVI, 149 complete echocardiographic data sets were available for the assessment of the indexed EOA (iEOA). In total, 106 CoreValve prostheses and 43 Sapien prostheses were implanted in this high-risk cohort (mean age 81 +/- 6 years, mean logistic EuroSCORE 20 +/- 13%).
RESULTS: The overall incidence of PPM (iEOA < 0.85 cm2/m2) was 61%. Patients with a larger body surface area were more likely to develop PPM (p = 0.001), while the prosthesis type, native annulus diameter, preoperative EOA, gender and prosthesis size had no influence. The mean aortic gradient was significantly higher in patients with PPM. A reduction in the left ventricular end-diastolic diameter was seen in all patients, without significant differences between groups. There were no differences in postoperative NYHA class or self-assessed health state between patients with or without PPM.
CONCLUSION: PPM was common after TAVI in the presented cohort, presumably because the native calcium masses narrow the outflow area available for blood flow. As expected for low gradients, there was no impairment of left ventricular dimension regression or clinical state of the patients, even if severe PPM was present. Based on the presented data, it is assumed that PPM might be less relevant in TAVI patients.

Entities:  

Mesh:

Year:  2013        PMID: 24151756

Source DB:  PubMed          Journal:  J Heart Valve Dis        ISSN: 0966-8519


  6 in total

Review 1.  Sex-Specific Considerations in Women with Aortic Stenosis and Outcomes After Transcatheter Aortic Valve Replacement.

Authors:  Christos G Mihos; Sheila L Klassen; Evin Yucel
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-06-19

2.  Impact of Prosthesis-Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement.

Authors:  Frédéric Poulin; Teerapat Yingchoncharoen; William M Wilson; Eric M Horlick; Philippe Généreux; E Murat Tuzcu; William Stewart; Mark D Osten; Anna Woo; Paaladinesh Thavendiranathan
Journal:  J Am Heart Assoc       Date:  2016-02-08       Impact factor: 5.501

3.  Patient-prosthesis mismatch in patients treated with transcatheter aortic valve implantation - predictors, incidence and impact on clinical efficacy. A preliminary study.

Authors:  Karol Zbroński; Bartosz Rymuza; Piotr Scisło; Kajetan Grodecki; Paulina Dobkowska; Marek Wawrzacz; Radosław Wilimski; Anna Słowikowska; Janusz Kochman; Krzysztof J Filipiak; Grzegorz Opolski; Zenon Huczek
Journal:  Postepy Kardiol Interwencyjnej       Date:  2017-11-29       Impact factor: 1.426

Review 4.  Clinical and Technical Challenges of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation.

Authors:  Pier Pasquale Leone; Fabio Fazzari; Francesco Cannata; Jorge Sanz-Sanchez; Antonio Mangieri; Lorenzo Monti; Ottavia Cozzi; Giulio Giuseppe Stefanini; Renato Bragato; Antonio Colombo; Bernhard Reimers; Damiano Regazzoli
Journal:  Front Cardiovasc Med       Date:  2021-06-04

5.  Incidence, Predictors and Outcome of Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Replacement: a Systematic Review and Meta-analysis.

Authors:  Yan-Biao Liao; Yi-Jian Li; Li Jun-Li; Zhen-Gang Zhao; Xin Wei; Jiay-Yu Tsauo; Tian-Yuan Xiong; Yuan-Ning Xu; Yuan Feng; Mao Chen
Journal:  Sci Rep       Date:  2017-11-08       Impact factor: 4.379

6.  Incidence, predictors, and outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement: A meta-analysis.

Authors:  Shixin He; Zhenfei Fang
Journal:  Medicine (Baltimore)       Date:  2020-06-12       Impact factor: 1.817

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.