Literature DB >> 24150637

Oxygen uptake kinetics during incremental- and decremental-ramp cycle ergometry.

Fadil Ozyener1, Harry B Rossiter, Susan A Ward, Brian J Whipp.   

Abstract

The pulmonary oxygen uptake (VO2) response to incremental-ramp cycle ergometry typically demonstrates lagged-linear first-order kinetics with a slope of ~10-11 ml·min(-1)·W(-1), both above and below the lactate threshold (θL), i.e. there is no discernible VO2 slow component (or "excess" VO2) above θL. We were interested in determining whether a reverse ramp profile would yield the same response dynamics. Ten healthy males performed a maximum incremental -ramp (15-30 W·min(-1), depending on fitness). On another day, the work rate (WR) was increased abruptly to the incremental maximum and then decremented at the same rate of 15-30 W.min(-1) (step-decremental ramp). Five subjects also performed a sub-maximal ramp-decremental test from 90% of θL. VO2 was determined breath-by-breath from continuous monitoring of respired volumes (turbine) and gas concentrations (mass spectrometer). The incremental-ramp VO2-WR slope was 10.3 ± 0.7 ml·min(-1)·W(-1), whereas that of the descending limb of the decremental ramp was 14.2 ± 1.1 ml·min(-1)·W(-1) (p < 0.005). The sub-maximal decremental-ramp slope, however, was only 9. 8 ± 0.9 ml·min(-1)·W(-1): not significantly different from that of the incremental-ramp. This suggests that the VO2 response in the supra-θL domain of incremental-ramp exercise manifest not actual, but pseudo, first-order kinetics. Key pointsThe slope of the decremental-ramp response is appreciably greater than that of the incremental.The response dynamics in supra-θL domain of the incremental-ramp appear not to manifest actual first-order kinetics.The mechanisms underlying the different dynamic response behaviour for incremental and decremental ramps are presently unclear.

Entities:  

Keywords:  Oxygen uptake-work rate gain; decremental-ramp exercise; incremental-ramp exercise; system linearity.

Year:  2011        PMID: 24150637      PMCID: PMC3737826     

Source DB:  PubMed          Journal:  J Sports Sci Med        ISSN: 1303-2968            Impact factor:   2.988


  33 in total

1.  Influence of exercise intensity on the on- and off-transient kinetics of pulmonary oxygen uptake in humans.

Authors:  F Ozyener; H B Rossiter; S A Ward; B J Whipp
Journal:  J Physiol       Date:  2001-06-15       Impact factor: 5.182

2.  Effects of prior heavy exercise on phase II pulmonary oxygen uptake kinetics during heavy exercise.

Authors:  M Burnley; A M Jones; H Carter; J H Doust
Journal:  J Appl Physiol (1985)       Date:  2000-10

3.  Linear and nonlinear characteristics of oxygen uptake kinetics during heavy exercise.

Authors:  T J Barstow; P A Molé
Journal:  J Appl Physiol (1985)       Date:  1991-12

4.  Cardiorespiratory transients in exercising man. I. Tests of superposition.

Authors:  Y Fujihara; J R Hildebrandt; J Hildebrandt
Journal:  J Appl Physiol       Date:  1973-07       Impact factor: 3.531

5.  On-line computer analysis and breath-by-breath graphical display of exercise function tests.

Authors:  W L Beaver; K Wasserman; B J Whipp
Journal:  J Appl Physiol       Date:  1973-01       Impact factor: 3.531

6.  Breath-by-breath measurement of true alveolar gas exchange.

Authors:  W L Beaver; N Lamarra; K Wasserman
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1981-12

7.  Delayed kinetics of respiratory gas exchange in the transition from prior exercise.

Authors:  R L Hughson; M Morrissey
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1982-04

8.  Mechanical efficiency and fatigue of fast and slow muscles of the mouse.

Authors:  C J Barclay
Journal:  J Physiol       Date:  1996-12-15       Impact factor: 5.182

9.  The O2 cost of the tension-time integral in isolated single myocytes during fatigue.

Authors:  Russell T Hepple; Richard A Howlett; Casey A Kindig; Creed M Stary; Michael C Hogan
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2010-02-03       Impact factor: 3.619

10.  Oxygen uptake kinetics from ramp work tests: variability of single test values.

Authors:  R L Hughson; M D Inman
Journal:  J Appl Physiol (1985)       Date:  1986-07
View more
  6 in total

1.  The contribution of "resting" body muscles to the slow component of pulmonary oxygen uptake during high-intensity cycling.

Authors:  Fadil Ozyener; Brian J Whipp; Susan A Ward
Journal:  J Sports Sci Med       Date:  2012-12-01       Impact factor: 2.988

2.  Long maximal incremental tests accurately assess aerobic fitness in class II and III obese men.

Authors:  Stefano Lanzi; Franco Codecasa; Mauro Cornacchia; Sabrina Maestrini; Paolo Capodaglio; Amelia Brunani; Paolo Fanari; Alberto Salvadori; Davide Malatesta
Journal:  PLoS One       Date:  2015-04-13       Impact factor: 3.240

3.  Cardiorespiratory and metabolic responses to body mass-based squat exercise in young men.

Authors:  Miki Haramura; Yohei Takai; Takaya Yoshimoto; Masayoshi Yamamoto; Hiroaki Kanehisa
Journal:  J Physiol Anthropol       Date:  2017-02-08       Impact factor: 2.867

4.  Dissociating external power from intramuscular exercise intensity during intermittent bilateral knee-extension in humans.

Authors:  Matthew J Davies; Alan P Benson; Daniel T Cannon; Simon Marwood; Graham J Kemp; Harry B Rossiter; Carrie Ferguson
Journal:  J Physiol       Date:  2017-09-02       Impact factor: 5.182

5.  Incremental and decremental cardiopulmonary exercise testing protocols produce similar maximum oxygen uptake in athletes.

Authors:  Nuno Manuel Frade de Sousa; Danilo Rodrigues Bertucci; Gabriel Medeiros de Sant'Ana; Pedro Luiz Ribeiro Angelucci Padua; Diogo Mello da Rosa
Journal:  Sci Rep       Date:  2021-06-23       Impact factor: 4.379

6.  Response to Letter to the editors of Hopkins et al.: Effects of surgical and FFP2/N95 face masks on cardiopulmonary exercise capacity: the numbers do not add up.

Authors:  Sven Fikenzer; Ulrich Laufs
Journal:  Clin Res Cardiol       Date:  2020-10-09       Impact factor: 5.460

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.