Intramuscular temperature differences between the mid-point and peripheral effective radiating area with ultrasound.

Michale G Miller1, Janae R Longoria, Christopher C Cheatham, Robert J Baker, Timothy J Michael.   

Abstract

The purpose of the study was to determine whether uniform intramuscular heating is achieved throughout a treatment area 2 times the transducer head at both 1 and 3 MHz. Seven male and three female subjects (Age: 23.6 ± 1.0 yrs, Weight: 83.8 ± 23.2 kg, Site Skinfold: 13.9 ± 7.3 mm) underwent two ultrasound treatments (1 and 3 MHz) in the triceps surae muscle group. Thermocouples were inserted at the midpoint and periphery of the treatment area. Ten minute baseline temperatures were recorded followed by a ten minute ultrasound treatment. Two (site) X 10 (time) repeated measures ANOVAs were separately used to determine significance for 1 and 3 MHz treatments. Post-hoc testing was performed using the Bonferroni adjustment. A significant site-by-time interaction was observed for both the 1 and 3 MHz treatments. From baseline to the end of the treatment, temperature increased approximately 2.62°C and 1.58°C for the midpoint and periphery of the 1 MHz treatment and 5.88°C and 3.64°C for the 3 MHz treatment. The differences in temperature suggest that uniform heating does not occur throughout the treatment area. Key points3 MHz is more effective in raising intramuscular temperature within ERA.Stroke count/rate of transducer may play a factor in heating tissue.Treatment size may alter uniform heating.

Entities:  

Keywords:  Tissue; acoustical.; thermal effects

Year:  2008        PMID: 24149462      PMCID: PMC3761457     

Source DB:  PubMed          Journal:  J Sports Sci Med        ISSN: 1303-2968            Impact factor:   2.988


  30 in total

1.  Identical 3-MHz ultrasound treatments with different devices produce different intramuscular temperatures.

Authors:  Mark A Merrick; Kristy D Bernard; Steven T Devor; M John M Williams
Journal:  J Orthop Sports Phys Ther       Date:  2003-07       Impact factor: 4.751

2.  Intramuscular Temperature Rises With Topical Analgesics Used as Coupling Agents During Therapeutic Ultrasound.

Authors:  J William Myrer; Gary J. Measom; Gilbert W. Fellingham
Journal:  J Athl Train       Date:  2001-03       Impact factor: 2.860

3.  Effect of transducer velocity on intramuscular temperature during a 1-MHz ultrasound treatment.

Authors:  Stephanie L Weaver; Timothy J Demchak; Marcus B Stone; Jody B Brucker; Phillip O Burr
Journal:  J Orthop Sports Phys Ther       Date:  2006-05       Impact factor: 4.751

4.  Analysis of effective radiating area, power, intensity, and field characteristics of ultrasound transducers.

Authors:  Lennart D Johns; Stephen J Straub; Samuel M Howard
Journal:  Arch Phys Med Rehabil       Date:  2007-01       Impact factor: 3.966

5.  Therapeutic ultrasound: the effects upon cutaneous blood flow in humans.

Authors:  J Gareth Noble; Victoria Lee; Faye Griffith-Noble
Journal:  Ultrasound Med Biol       Date:  2007-02       Impact factor: 2.998

6.  Effect of superficial heat, deep heat, and active exercise warm-up on the extensibility of the plantar flexors.

Authors:  C A Knight; C R Rutledge; M E Cox; M Acosta; S J Hall
Journal:  Phys Ther       Date:  2001-06

7.  The effect of therapeutic ultrasound on repair of the achilles tendon (tendo calcaneus) of the rat.

Authors:  A da Cunha; N A Parizotto; B de C Vidal
Journal:  Ultrasound Med Biol       Date:  2001-12       Impact factor: 2.998

Review 8.  A new direction for ultrasound therapy in sports medicine.

Authors:  Stuart J Warden
Journal:  Sports Med       Date:  2003       Impact factor: 11.136

9.  Human Tissue-Temperature Rise During Ultrasound Treatments With the Aquaflex Gel Pad.

Authors:  Sunnee Bishop; David O. Draper; Kenneth L. Knight; J Brent Feland; Dennis Eggett
Journal:  J Athl Train       Date:  2004-06       Impact factor: 2.860

10.  Heat distribution in the lower leg from pulsed short-wave diathermy and ultrasound treatments.

Authors:  C L Garrett; D O Draper; K L Knight
Journal:  J Athl Train       Date:  2000-01       Impact factor: 2.860

View more
  1 in total

1.  Experimental Verification of Modeled Thermal Distribution Produced by a Piston Source in Physiotherapy Ultrasound.

Authors:  M I Gutierrez; S A Lopez-Haro; A Vera; L Leija
Journal:  Biomed Res Int       Date:  2016-11-23       Impact factor: 3.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.