Literature DB >> 24149230

Strength Performance Assessment in a Simulated Men's Gymnastics Still Rings Cross.

Jennifer K Dunlavy1, William A Sands, Jeni R McNeal, Michael H Stone, Sarah L Smith, Monem Jemni, G Gregory Haff.   

Abstract

Athletes in sports such as the gymnastics who perform the still rings cross position are disadvantaged due to a lack of objective and convenient measurement methods. The gymnastics "cross "is a held isometric strength position considered fundamental to all still rings athletes. The purpose of this investigation was to determine if two small force platforms (FPs) placed on supports to simulate a cross position could demonstrate the fidelity necessary to differentiate between athletes who could perform a cross from those who could not. Ten gymnasts (5 USA Gymnastics, Senior National Team, and 5 Age Group Level Gymnasts) agreed to participate. The five Senior National Team athletes were grouped as cross Performers; the Age Group Gymnasts could not successfully perform the cross position and were grouped as cross Non- Performers. The two small FPs were first tested for reliability and validity and were then used to obtain a force-time record of a simulated cross position. The simulated cross test consisted of standing between two small force platforms placed on top of large solid gymnastics spotting blocks. The gymnasts attempted to perform a cross position by placing their hands at the center of the FPs and pressing downward with sufficient force that they could remove the support of their feet from the floor. Force-time curves (100 Hz) were obtained and analyzed for the sum of peak and mean arm ground reaction forces. The summed arm forces, mean and peak, were compared to body weight to determine how close the gymnasts came to achieving forces equal to body weight and thus the ability to perform the cross. The mean and peak summed arm forces were able to statistically differentiate between athletes who could perform the cross from those who could not (p < 0.05). The force-time curves and small FPs showed sufficient fidelity to differentiate between Performer and Non- Performer groups. This experiment showed that small and inexpensive force platforms may serve as useful adjuncts to athlete performance measurement such as the gymnastics still rings cross. Key pointsStrength-related skills are difficult to assess in some sports and thus require special means.Small force platforms have sufficient fidelity to assess the differences between gymnasts who can perform a still rings cross from those who cannot.Strength assessment via small force platforms may serve as a means of assessing skill readiness, strength symmetry, and progress in learning a still rings cross.

Entities:  

Keywords:  Portable force platform; field test

Year:  2007        PMID: 24149230      PMCID: PMC3778705     

Source DB:  PubMed          Journal:  J Sports Sci Med        ISSN: 1303-2968            Impact factor:   2.988


  2 in total

1.  Surface electromyography of nine shoulder muscles in two iron cross conditions in gymnastics.

Authors:  S Bernasconi; N Tordi; B Parratte; J D D Rouillon; G Monnier
Journal:  J Sports Med Phys Fitness       Date:  2004-09       Impact factor: 1.637

2.  Reliability theory and research decision in selection of a criterion score.

Authors:  W Kroll
Journal:  Res Q       Date:  1967-10
  2 in total
  2 in total

1.  Maximum Strength Benchmarks for Difficult Static Elements on Rings in Male Elite Gymnastics.

Authors:  Christoph Schärer; Sarina Huber; Pascal Bucher; Claudio Capelli; Klaus Hübner
Journal:  Sports (Basel)       Date:  2021-05-28

2.  Specific Eccentric-Isokinetic Cluster Training Improves Static Strength Elements on Rings for Elite Gymnasts.

Authors:  Christoph Schärer; Lisa Tacchelli; Beat Göpfert; Micah Gross; Fabian Lüthy; Wolfgang Taube; Klaus Hübner
Journal:  Int J Environ Res Public Health       Date:  2019-11-18       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.