Accuracy of the concentration of morphine infusions prepared for patients in a neonatal intensive care unit.

Virginia Aguado-Lorenzo1, Kevin Weeks, Paul Tunstell, Karen Turnock, Timothy Watts, Sara Arenas-Lopez.   

Abstract

OBJECTIVE: To investigate the accuracy of morphine infusions prepared for neonates in relation to the label strength and to identify the differences in deviation between infusions made in neonatal intensive care unit (NICU) and those dispensed ready-to-use from pharmacy.
METHODS: Unused portions of morphine solution for infusion were collected over a 6-weeks period and used to determine the concentration of the drug by high-performance liquid chromatography (HPLC).
RESULTS: A total of 19.2% of infusions prepared by nurses in the ward and 7.8% prepared in the pharmacy were outside the limit required by the British Pharmacopoeia (±7.5%). Moreover, a deviation in concentration of more than 20% was found in ward-prepared infusions, although this was caused by volume discrepancies of less than 0.2 mL. The frequency and magnitude of deviations found in infusions prepared in pharmacy was lower than in those prepared by NICU. The latter showed significantly higher number of out-of-specification samples (p=0.015); however, deviations from intended concentration occurred in both settings. Significant differences between pharmacy and NICU for volumes of less than 0.5 mL or for less than 1 mL were not identified probably due to small sample size, but statistical data show a trend for differences.
CONCLUSIONS: Current practice of preparation of infusions from strengths intended for older children and adults involves dilution of small volumes in a syringe and leads to inaccuracy in the final concentration of infusions for neonatal use. We propose the implementation of standard concentrations for this patient group to effectively eliminate these errors.

Entities:  

Keywords:  accuracy; infusion; morphine; neonates; standard concentrations

Mesh:

Substances:

Year:  2013        PMID: 24148890     DOI: 10.1136/archdischild-2013-304522

Source DB:  PubMed          Journal:  Arch Dis Child        ISSN: 0003-9888            Impact factor:   3.791


  14 in total

1.  Adverse drug reactions in neonates and infants: a population-tailored approach is needed.

Authors:  Karel Allegaert; Johannes N van den Anker
Journal:  Br J Clin Pharmacol       Date:  2015-06-01       Impact factor: 4.335

Review 2.  Pain management in newborns.

Authors:  Richard W Hall; Kanwaljeet J S Anand
Journal:  Clin Perinatol       Date:  2014-10-07       Impact factor: 3.430

3.  Prevalence, Causes and Severity of Medication Administration Errors in the Neonatal Intensive Care Unit: A Systematic Review and Meta-Analysis.

Authors:  Josephine Henry Basil; Chandini Menon Premakumar; Adliah Mhd Ali; Nurul Ain Mohd Tahir; Noraida Mohamed Shah
Journal:  Drug Saf       Date:  2022-10-03       Impact factor: 5.228

4.  Sources and magnitude of error in preparing morphine infusions for nurse-patient controlled analgesia in a UK paediatric hospital.

Authors:  Asia N Rashed; Stephen Tomlin; Virginia Aguado; Ben Forbes; Cate Whittlesea
Journal:  Int J Clin Pharm       Date:  2016-08-08

5.  Strategies implementation to reduce medicine preparation error rate in neonatal intensive care units.

Authors:  Ainara Campino; Elena Santesteban; Pilar Pascual; Beatriz Sordo; Casilda Arranz; Maria Unceta; Ion Lopez-de-Heredia
Journal:  Eur J Pediatr       Date:  2015-12-15       Impact factor: 3.183

Review 6.  Intravenous medicine preparation technique training programme for nurses in clinical areas.

Authors:  Ainara Campino; Beatriz Sordo; PIlar Pascual; Casilda Arranz; Elena Santesteban; Maria Unceta; Ion Lopez-de-Heredia
Journal:  Eur J Hosp Pharm       Date:  2017-06-06

Review 7.  Accuracy of intravenous and enteral preparations involving small volumes for paediatric use: a review.

Authors:  L P Ainscough; J L Ford; C W Morecroft; M Peak; M A Turner; A J Nunn; M Roberts
Journal:  Eur J Hosp Pharm       Date:  2017-01-04

Review 8.  Interventions to reduce medication errors in neonatal care: a systematic review.

Authors:  Minh-Nha Rhylie Nguyen; Cassandra Mosel; Luke E Grzeskowiak
Journal:  Ther Adv Drug Saf       Date:  2017-12-28

9.  Medicine preparation errors in ten Spanish neonatal intensive care units.

Authors:  Ainara Campino; Casilda Arranz; Maria Unceta; Miguel Rueda; Beatriz Sordo; Pilar Pascual; Ion Lopez-de-Heredia; Elena Santesteban
Journal:  Eur J Pediatr       Date:  2015-08-27       Impact factor: 3.183

10.  The feasibility of using dose-banded syringes to improve the safety and availability of patient-controlled opioid analgesic infusions in children.

Authors:  Asia N Rashed; Cate Whittlesea; Ben Forbes; Stephen Tomlin
Journal:  Eur J Hosp Pharm       Date:  2014-07-24
View more