Literature DB >> 24148453

Chemiluminescence detection of heroin in illicit drug samples.

Jessica M Terry1, Zoe M Smith, Jessica J Learey, R Andrew Shalliker, Neil W Barnett, Paul S Francis.   

Abstract

Heroin (3,6-diacetylmorphine) and several important extraction and synthesis impurities (morphine, 6-monoacetylmorphine, codeine and 6-acetylcodeine) were determined in illicit drug samples, using high performance liquid chromatography with 'parallel segmented flow', which enabled the simultaneous use of three complementary modes of detection (UV-absorbance, tris(2,2'-bipyridine)ruthenium(III) chemiluminescence and permanganate chemiluminescence). This rapid and sensitive approach for the analysis of street heroin was used to explore the chemistry of a proposed heroin screening test that is based on the relative response with these two chemiluminescence reagents using flow injection analysis. Although heroin was the major constituent of the six drug samples (between 16% and 67% by mass), the synthetic by-product 6-acetylcodeine (2.5-8.3%) made a greater contribution to the total [Ru(bipy)3](3+) chemiluminescence response of the screening test. The signal with permanganate was primarily due to the presence of 6-monoacetylmorphine (0.9-29%), and was therefore indicative of the degree of sample degradation during clandestine manufacture or poor storage conditions prior to the drug seizure. In the second part of the screening test, the sample is treated with sodium hydroxide, which results in a large increase in the signal with permanganate, due to the rapid hydrolysis of heroin to 6-monoacetylmorphine. As the emission of these two reagents with morphinan-alkaloids and their derivatives largely depends on the substituent at the O(3) position, the slower hydrolysis of 6-monoacetylmorphine to morphine, and 6-acetylcodeine to codeine, did not have a major impact on the characteristic pattern of responses in the screening test.
© 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chemiluminescence detection; Diacetylmorphine; Diamorphine; High performance liquid chromatography; Parallel segmented flow; Street drug samples

Mesh:

Substances:

Year:  2013        PMID: 24148453     DOI: 10.1016/j.talanta.2013.07.051

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  1 in total

1.  A lateral flow strip based on gold nanoparticles to detect 6-monoacetylmorphine in oral fluid.

Authors:  Jia Liu; Xiaolong Hu; Fangqi Cao; Yurong Zhang; Jianzhong Lu; Libo Zeng
Journal:  R Soc Open Sci       Date:  2018-06-27       Impact factor: 2.963

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.