Magnetic solid-phase extraction combined with graphite furnace atomic absorption spectrometry for speciation of Cr(III) and Cr(VI) in environmental waters.

Hong-mei Jiang1, Ting Yang, Yan-hong Wang, Hong-zhen Lian, Xin Hu.   

Abstract

A new approach of magnetic solid phase extraction (MSPE) coupled with graphite furnace atomic absorption spectrometry (GFAAS) has been developed for the speciation of Cr(III) and Cr(VI) using zincon-immobilized silica-coated magnetic Fe3O4 nanoparticles (Zincon-Si-MNPs) as the MSPE absorbent. Cr(III) was quantitatively reserved on the absorbent at pH 9.1 while total Cr was reserved at pH 6.5. The absorbed Cr species were eluted by using 2 mol/L HCl and detected by GFAAS. The concentration of Cr(VI) could be calculated by subtracting Cr(III) from total Cr. All the parameters affecting the separation and extraction efficiency of Cr species such as pH, extraction time, concentration and volume of eluent, sample volume and influence of co-existing ions were systematically examined and the optimized conditions were established accordingly. The detection limit (LOD) of the method was 0.016 and 0.011 ng mL(-1) for Cr(III) and Cr(VI), respectively, with the enrichment factor of 100 and 150. The precisions of this method (Relative standard deviation, RSD, n=7) for Cr(III) and Cr(VI) at 0.1 ng mL(-1) were 6.0% and 6.2%, respectively. In order to validate the proposed method, a certified reference material of environmental water was analyzed, and the result of Cr speciation was in good agreement with the certified value. This MSPE-GFAAS method has been successfully applied for the speciation of Cr(III) and Cr(VI) in lake and tap waters with the recoveries of 88-109% for the spiked samples. Moreover, the MSPE separation mechanism of Cr(III) and Cr(VI) based on their adsorption-desorption on Zincon-Si-MNPs has been explained through various spectroscopic characterization.
© 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chromium; FAAS; GFAAS; Graphite furnace atomic absorption spectrometry (GFAAS); ICP–MS; ICP–OES; LOD; MNPs; Magnetic nanoparticles; RSD; SPE; Si–MNPs; Solid phase extraction (SPE); Speciation; Zincon; Zincon–Si–MNPs; flame atomic absorption spectrometry; graphite furnace atomic absorption spectrometry; inductively coupled plasma optical emission spectrometry; inductively coupled plasma–mass spectrometry; limit of detection; magnetic Fe(3)O(4) nanoparticles; relative standard deviation; silica-coated magnetic Fe(3)O(4) nanoparticles; solid-phase extraction; zincon-immobilized silica-coated magnetic Fe(3)O(4) nanoparticles

Mesh:

Substances:

Year:  2013        PMID: 24148416     DOI: 10.1016/j.talanta.2013.05.008

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Magnetic Solid-Phase Extraction Using Fe3O4@SiO2 Magnetic Nanoparticles Followed by UV-Vis Spectrometry for Determination of Paraquat in Plasma and Urine Samples.

Authors:  Ou Sha; Yu Wang; Xin Yin; Xiaobing Chen; Li Chen; Shujun Wang
Journal:  J Anal Methods Chem       Date:  2017-07-17       Impact factor: 2.193

2.  Environmental exposure to arsenic and chromium in an industrial area.

Authors:  Luigi Vimercati; Maria F Gatti; Tommaso Gagliardi; Francesco Cuccaro; Luigi De Maria; Antonio Caputi; Marco Quarato; Antonio Baldassarre
Journal:  Environ Sci Pollut Res Int       Date:  2017-03-20       Impact factor: 4.223

3.  Speciation of chromium in waters using dispersive micro-solid phase extraction with magnetic ferrite and graphite furnace atomic absorption spectrometry.

Authors:  Ignacio López-García; Juan José Marín-Hernández; Manuel Hernández-Córdoba
Journal:  Sci Rep       Date:  2020-03-24       Impact factor: 4.379

  3 in total