Literature DB >> 24148391

Carbon nanotubes reinforced hollow fiber solid phase microextraction for the determination of strychnine and brucine in urine.

Xin-Yue Song1, Yan-Ping Shi, Juan Chen.   

Abstract

A mixed matrix membrane (MMM), based on carbon nanotubes (CNTs) and hollow fiber (HF), was prepared and combined with solid phase microextraction (SPME) mode to determine strychnine and brucine in urine. This MMM was prepared by dispersing CNTs in water via surfactant assistance, and then immobilizing CNTs into the pores of HF by capillary forces and sonification. The prepared carbon nanotubes reinforced hollow fiber (CNTs-HF) was subsequently wetted by a few microliters of organic solvent (1-octanol), and then applied to extract the target analytes in direct immersion sampling mode. After extraction, analytes were desorbed via ultrasonic-assisted effect, and then detected via high-performance liquid chromatography (HPLC). To achieve the highest extraction efficiency, main extraction parameters such as the type and amount of surfactant, the diameter and doping level of CNTs, extraction time, desorption condition, pH value, stirring rate and volume of the donor phase were optimized. Under the optimum extraction conditions, the method showed good linearity ranges with correlation coefficients higher than 0.9990, good repeatability and batch-to-batch reproducibility with relative standard deviations (RSDs) less than 6% and 5% for strychnine and brucine, respectively, and low limits of detection (0.7 and 0.9 µg L(-1) for strychnine and brucine, respectively). The recoveries were in the range of 83.81-116.14% at three spiked levels. The developed method was successfully applied to real urine sample with mean relative recoveries of 94.28% and 91.30% for strychnine and brucine, respectively. The developed method shows comparable results against reference methods and is a simple, green, and cost-effective microextraction technique.
© 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Brucine; CNTs–HF; CNTs–HF-SPME; HF; HF-SPME; HPLC; HPLC-PDA; Hollow fiber; MMM; MWCNTs; Multi-walled carbon nanotubes; Solid-phase microextraction; Strychnine; Surfactant; carbon nanotubes reinforced hollow fiber; carbon nanotubes reinforced hollow fiber solid-phase microextraction; high-performance liquid chromatography; high-performance liquid chromatography photodiode array detection; hollow fiber; hollow fiber solid-phase microextraction; mixed matrix membrane; multi-walled carbon nanotubes

Mesh:

Substances:

Year:  2013        PMID: 24148391     DOI: 10.1016/j.talanta.2013.05.025

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Solid/liquid phase microextraction of five bisphenol-type endocrine disrupting chemicals by using a hollow fiber reinforced with graphene oxide nanoribbons, and determination by HPLC-PDA.

Authors:  Xiaofei Han; Juan Chen; Hongdeng Qiu; Yan-Ping Shi
Journal:  Mikrochim Acta       Date:  2019-05-24       Impact factor: 5.833

2.  The Production and Evaluation of an Electrochemical Sensors for Strychnine and Its Main Metabolite Strychnine N-Oxide for Their Use in Biological Samples.

Authors:  Bakhtiyar Qader; Issam Hussain; Mark Baron; Rafael Estevez-Brito; John Paul Cassella; Jose Gonzalez-Rodriguez
Journal:  Molecules       Date:  2022-03-11       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.