Literature DB >> 24147994

Piezoelectric vs. conventional drilling in implant site preparation: pilot controlled randomized clinical trial with crossover design.

Luigi Canullo1, David Peñarrocha, Miguel Peñarrocha, Alonso-Gonzalez Rocio, Maria Penarrocha-Diago.   

Abstract

OBJECTIVE: To compare implant stability throughout osseointegration, peri-implant marginal bone loss, and success rates of implants placed with conventional and mixed drilling/piezoelectric osteotomy.
MATERIALS AND METHODS: A pilot randomized-controlled trial was performed on 15 patients. Each patient received two implants in the mandibular molar region. All sites were prepared with conventionally up to the 2.8 mm wide drill. Osteotomies were randomly finalized with a 3 mm diameter drill (control group) or with two consecutive ultrasonic tips (2.8 mm and 3 mm wide, respectively) (test group). Resonance frequency analysis measurements were taken at implant placement and after 1, 3, 8, and 12 weeks. Peri-implant marginal bone loss 12 months after loading was calculated using periapical radiographs. Wilcoxon test for related samples was used to study differences in implant stability and in peri-implant marginal bone loss between the two groups.
RESULTS: Twenty-nine of 30 implants osseointegrated successfully (one failure in the control group). Stability was significantly higher in the test group at the 8th week assessment; differences were non-significant at all other time-points. Longitudinally, differences were observed between the patterns of implant stability changes: in the test group stability increased more progressively, while in the control group an abrupt change occurred between the 8th and 12th weeks assessments. No difference was found in peri-implant marginal bone loss between the groups. All 29 implants were functionally successful at the 15-month visit.
CONCLUSIONS: Within the limit of this pilot study (small sample size, short follow-up), data suggested that implant stability might develop slightly faster when implant site osteotomy is performed with a mixed drilling/ultrasonic technique.
© 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  implant stability; piezosurgery; randomized clinical trial; ultrasounds

Mesh:

Year:  2013        PMID: 24147994     DOI: 10.1111/clr.12278

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  5 in total

1.  Healing at implants installed in osteotomies prepared either with a piezoelectric device or drills: an experimental study in dogs.

Authors:  Shigeo Fujiwara; Shingo Kato; Franco Bengazi; Joaquin Urbizo Velez; Margherita Tumedei; Mitsuo Kotsu; Daniele Botticelli
Journal:  Oral Maxillofac Surg       Date:  2020-08-15

2.  [Piezosurgery for surgically assisted rapid maxillary expansion under local anesthesia].

Authors:  Hao Sun; Biao Li; Hao Sun; Zhixu Liu; Xudong Wang
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2014-08

3.  Hybrid Funnel Technique: A Novel Approach for Implant Site Preparation: A Pilot Study.

Authors:  Luigi Canullo; Roberta Iacono; Eduardo Pires Godoy; Andrea Punzo; Alessio Cavicchia; Francesco Gianfreda; Patrizio Bollero
Journal:  Dent J (Basel)       Date:  2022-08-25

4.  Effectiveness of methods for detaching orthodontic implants likely to fracture upon rotational torque - an animal study.

Authors:  Susumu Nakagaki; Masahiro Iijima; Yoshitaka Yasuda; Keisuke Handa; Toshiyuki Koike; Takashi Saito; Itaru Mizoguchi
Journal:  Clin Exp Dent Res       Date:  2016-02-09

5.  Immediate Loading of Implant-Supported Single Crowns after Conventional and Ultrasonic Implant Site Preparation: A Multicenter Randomized Controlled Clinical Trial.

Authors:  Claudio Stacchi; Teresa Lombardi; Domenico Baldi; Calogero Bugea; Antonio Rapani; Giuseppe Perinetti; Angelo Itri; David Carpita; Guido Audenino; Giuseppe Bianco; Simone Verardi; Stefano Carossa; Gianmario Schierano
Journal:  Biomed Res Int       Date:  2018-08-14       Impact factor: 3.411

  5 in total