Literature DB >> 24147953

Porous titanium-6 aluminum-4 vanadium cage has better osseointegration and less micromotion than a poly-ether-ether-ketone cage in sheep vertebral fusion.

Su-Hua Wu1, Yi Li, Yong-Quan Zhang, Xiao-Kang Li, Chao-Fan Yuan, Yu-Lin Hao, Zhi-Yong Zhang, Zheng Guo.   

Abstract

Interbody fusion cages made of poly-ether-ether-ketone (PEEK) have been widely used in clinics for spinal disorders treatment; however, they do not integrate well with surrounding bone tissue. Ti-6Al-4V (Ti) has demonstrated greater osteoconductivity than PEEK, but the traditional Ti cage is generally limited by its much greater elastic modulus (110 GPa) than natural bone (0.05-30 GPa). In this study, we developed a porous Ti cage using electron beam melting (EBM) technique to reduce its elastic modulus and compared its spinal fusion efficacy with a PEEK cage in a preclinical sheep anterior cervical fusion model. A porous Ti cage possesses a fully interconnected porous structure (porosity: 68 ± 5.3%; pore size: 710 ± 42 μm) and a similar Young's modulus as natural bone (2.5 ± 0.2 GPa). When implanted in vivo, the porous Ti cage promoted fast bone ingrowth, achieving similar bone volume fraction at 6 months as the PEEK cage without autograft transplantation. Moreover, it promoted better osteointegration with higher degree (2-10x) of bone-material binding, demonstrated by histomorphometrical analysis, and significantly higher mechanical stability (P < 0.01), shown by biomechanical testing. The porous Ti cage fabricated by EBM could achieve fast bone ingrowth. In addition, it had better osseointegration and superior mechanical stability than the conventional PEEK cage, demonstrating great potential for clinical application.
© 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

Entities:  

Keywords:  Electron beam melting; Fusion cage; Intervertebral fusion; Porous material; Titanium-6 Aluminum-4 Vanadium

Mesh:

Substances:

Year:  2013        PMID: 24147953     DOI: 10.1111/aor.12153

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  29 in total

Review 1.  Multi-Scale Surface Treatments of Titanium Implants for Rapid Osseointegration: A Review.

Authors:  Qingge Wang; Peng Zhou; Shifeng Liu; Shokouh Attarilar; Robin Lok-Wang Ma; Yinsheng Zhong; Liqiang Wang
Journal:  Nanomaterials (Basel)       Date:  2020-06-26       Impact factor: 5.076

2.  PEEK versus metal cages in posterior lumbar interbody fusion: a clinical and radiological comparative study.

Authors:  F Cuzzocrea; A Ivone; E Jannelli; A Fioruzzi; E Ferranti; R Vanelli; F Benazzo
Journal:  Musculoskelet Surg       Date:  2018-12-10

Review 3.  An analysis of spine fusion outcomes in sheep pre-clinical models.

Authors:  Emily M Lindley; Cameron Barton; Thomas Blount; Evalina L Burger; Christopher M J Cain; Howard B Seim; A Simon Turner; Vikas V Patel
Journal:  Eur Spine J       Date:  2016-05-10       Impact factor: 3.134

4.  Do Surface Porosity and Pore Size Influence Mechanical Properties and Cellular Response to PEEK?

Authors:  F Brennan Torstrick; Nathan T Evans; Hazel Y Stevens; Ken Gall; Robert E Guldberg
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

5.  Arthrodesis Rate and Patient Reported Outcomes After Anterior Lumbar Interbody Fusion Utilizing a Plasma-Sprayed Titanium Coated PEEK Interbody Implant: A Retrospective, Observational Analysis.

Authors:  Joseph A Sclafani; Sophea R Bergen; Miranda Staples; Kevin Liang; Ramin Raiszadeh
Journal:  Int J Spine Surg       Date:  2017-01-13

6.  A study on the mechanical characteristics of the EBM-printed Ti-6Al-4V LCP plates in vitro.

Authors:  Peng-Cheng Liu; Yun-Ji Yang; Run Liu; He-Xi Shu; Jin-Peng Gong; Yong Yang; Qi Sun; Xing Wu; Ming Cai
Journal:  J Orthop Surg Res       Date:  2014-11-05       Impact factor: 2.359

7.  Biocompatibility of Four Common Orthopedic Biomaterials Following a High-Salt Diet: An In Vivo Study.

Authors:  Mathieu Lecocq; Cécile Bernard; Marie Solenne Felix; Jean-Marc Linares; Julien Chaves-Jacob; Patrick Decherchi; Erick Dousset
Journal:  Int J Mol Sci       Date:  2017-07-11       Impact factor: 5.923

8.  Laser beam melting 3D printing of Ti6Al4V based porous structured dental implants: fabrication, biocompatibility analysis and photoelastic study.

Authors:  Fei Yang; Chen Chen; QianRong Zhou; YiMing Gong; RuiXue Li; ChiChi Li; Florian Klämpfl; Sebastian Freund; XingWen Wu; Yang Sun; Xiang Li; Michael Schmidt; Duan Ma; YouCheng Yu
Journal:  Sci Rep       Date:  2017-03-28       Impact factor: 4.379

9.  Does PEEK/HA Enhance Bone Formation Compared With PEEK in a Sheep Cervical Fusion Model?

Authors:  William R Walsh; Matthew H Pelletier; Nicky Bertollo; Chris Christou; Chris Tan
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

10.  The Effect of Uncinate Process Resection on Subsidence Following Anterior Cervical Discectomy and Fusion.

Authors:  Su Hun Lee; Jun Seok Lee; Soon Ki Sung; Dong Wuk Son; Sang Weon Lee; Geun Sung Song
Journal:  J Korean Neurosurg Soc       Date:  2017-08-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.