Literature DB >> 24145841

Expanded measurements of intra-abdominal pressure do not increase the detection rate of intra-abdominal hypertension: a single-center observational study.

Annika Reintam Blaser1, Silver Sarapuu, Kadri Tamme, Joel Starkopf.   

Abstract

OBJECTIVE: Intra-abdominal hypertension may contribute to a poor outcome. Whether limiting intra-abdominal pressure measurements to preselected at-risk patients allows for sufficient detection of intra-abdominal hypertension is unclear. We aimed to clarify whether expanded intra-abdominal pressure monitoring results in an increased detection rate of intra-abdominal hypertension.
DESIGN: Retrospective observational study.
SETTING: General ICU of University Hospital. PATIENTS: Consecutive adult ICU patients from 2004 to 2011.
INTERVENTIONS: Intra-abdominal pressure measurements in predefined at-risk patients.
MEASUREMENTS AND MAIN RESULTS: Prospectively collected data of 2,696 admissions were divided into three subgroups according to the intra-abdominal pressure measurement policy in different years: 1) 2004-2005, mechanically ventilated patients with at least one additional risk factor for intra-abdominal hypertension (multiple trauma, abdominal surgery, pancreatitis, post-cardiopulmonary resuscitation, fluid resuscitation > 5 L/24 hr, vasoactive or inotropic support, and renal replacement therapy); 2) 2006-2009, all mechanically ventilated patients expected to stay for more than or equal to 24 hours; and 3) 2010-2011, mechanically ventilated patients with a body mass index greater than 30 kg/m, positive end-expiratory pressure more than 10 cm H2O, PaO2/FIO2 less than 300, use of vasopressors/inotropes, pancreatitis, hepatic failure/cirrhosis with ascites, gastrointestinal bleeding, or postlaparotomy. In all, 2,696 patients were studied, and 1,241 patients (46.0%) underwent intra-abdominal pressure monitoring. The intra-abdominal pressure was measured in 31.7%, 55.6%, and 41.1% of patients during the first, second, and third time periods (p < 0.001), and intra-abdominal hypertension (intra-abdominal pressure ≥ 12 mm Hg) occurred in 19.9%, 20.3%, and 20.1% of patients, respectively (p = 0.972). The mean intra-abdominal pressure at admission day was an independent predictor of mortality in patients with intra-abdominal pressure measurements started within the first 24 hours (odds ratio, 1.046 [95% CI, 1.019-1.072]). The mortality of patients with intra-abdominal hypertension was 29.8% versus 18.6% in those without intra-abdominal hypertension (p < 0.001).
CONCLUSIONS: Expanding the measurement of intra-abdominal pressure to more than 50% of intensive care admissions does not increase the detection rate of intra-abdominal hypertension. In patients with intra-abdominal pressure monitoring, the mean intra-abdominal pressure on the admission day is an independent predictor of mortality.

Entities:  

Mesh:

Year:  2014        PMID: 24145841     DOI: 10.1097/CCM.0b013e3182a6459b

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  4 in total

1.  Intra-abdominal pressure: Time ripe to revise management guidelines of acute pancreatitis?

Authors:  Jiten Jaipuria; Vimal Bhandari; Avneet Singh Chawla; Mohit Singh
Journal:  World J Gastrointest Pathophysiol       Date:  2016-02-15

Review 2.  Acute abdominal compartment syndrome: current diagnostic and therapeutic options.

Authors:  A Hecker; B Hecker; M Hecker; J G Riedel; M A Weigand; W Padberg
Journal:  Langenbecks Arch Surg       Date:  2015-10-30       Impact factor: 3.445

Review 3.  Mild to moderate intra-abdominal hypertension: Does it matter?

Authors:  Liivi Maddison; Joel Starkopf; Annika Reintam Blaser
Journal:  World J Crit Care Med       Date:  2016-02-04

4.  Intra-abdominal pressure in third trimester pregnancy complicated by acute pancreatitis: an observational study.

Authors:  Liqun Sun; Weiqin Li; Fuxi Sun; Yanxia Geng; Zhihui Tong; Jieshou Li
Journal:  BMC Pregnancy Childbirth       Date:  2015-09-22       Impact factor: 3.007

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.