Literature DB >> 24144372

Floc characterization and membrane fouling of polyferric-polymer dual/composite coagulants in coagulation/ultrafiltration hybrid process.

Hongyan Rong1, Baoyu Gao, Junchao Li, Bei Zhang, Shenglei Sun, Yan Wang, Qinyan Yue, Qian Li.   

Abstract

Papermaking sludge and spent pickling liquor were recycled to synthesize a macromolecular lignin-acrylamide polymer (LA) and polyferric chloride (PFC), respectively. The dual-coagulant PFC-LA (PFC and LA were dosed orderly), composite coagulant PFCLA (PFC and LA premixed before dosed) and PFC were used in coagulation/ultrafiltration hybrid process in surface water treatment. The objectives of this paper are to comparatively investigate final water quality after coagulation and coagulation/ultrafiltration process and floc properties, including floc size, strength, recoverability and floc structure, with or without LA addition. Additionally, the relationship between membrane fouling and floc characteristics was discussed. The results showed that best final water quality was obtained by PFC-LA, sequentially followed by PFCLA and PFC. Floc size, growth rate, strength and recoverability as well as fractal dimension were also in the order of PFC-LA>PFCLA>PFC. The maximum permeate fluxes before and after backwash operation were obtained by PFC-LA, which gave the largest and most compact flocs. Coagulation suspension after breakage resulted in much more serious membrane fouling for PFC, whereas permeate flux slightly decreased when LA was used in combination with PFC. Crown
Copyright © 2013. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Floc properties; Membrane fouling; Papermaking sludge; Spent pickling liquor

Year:  2013        PMID: 24144372     DOI: 10.1016/j.jcis.2013.09.013

Source DB:  PubMed          Journal:  J Colloid Interface Sci        ISSN: 0021-9797            Impact factor:   8.128


  2 in total

1.  Flocculation performance of lignin-based flocculant during reactive blue dye removal: comparison with commercial flocculants.

Authors:  Kangying Guo; Baoyu Gao; Ruihua Li; Wenyu Wang; Qinyan Yue; Yan Wang
Journal:  Environ Sci Pollut Res Int       Date:  2017-12-03       Impact factor: 4.223

2.  Comparative Evaluation of Aluminum Sulfate and Ferric Sulfate-Induced Coagulations as Pretreatment of Microfiltration for Treatment of Surface Water.

Authors:  Yali Song; Bingzhi Dong; Naiyun Gao; Yang Deng
Journal:  Int J Environ Res Public Health       Date:  2015-06-12       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.