Literature DB >> 24144176

Surgical technique: hand-over-hand retrieval of a posteriorly dislocated DSAEK graft in an eye with an iris reconstruction lens.

John A Wells, Anthony J Aldave, Irena Tsui.   

Abstract

Descemet's stripping automated endothelial keratoplasty (DSAEK) has become the preferred surgical treatment for corneal endothelial pathologies. An intraoperative complication of DSAEK is posterior dislocation of the donor graft into the vitreous cavity. As the number of performed DSAEK procedures grows each year, the possibility of encountering a posteriorly dislocated donor graft increases. The authors report a case of intraoperative graft dislocation and a novel hand-over-hand retrieval method from the retinal surface. The hand-over-hand method provides an added surgical strategy for rescuing grafts that have fallen into the vitreous cavity. Copyright 2013, SLACK Incorporated.

Entities:  

Mesh:

Year:  2013        PMID: 24144176     DOI: 10.3928/23258160-20131015-02

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers Imaging Retina        ISSN: 2325-8160            Impact factor:   1.300


  1 in total

1.  An Unusual Case of DMEK Graft Loss into the Vitreous and Its Successful Retrieval and Survival.

Authors:  Khaled Helaiwa; Kai Januschowski; Karl T Boden; Annekatrin Rickmann
Journal:  Case Rep Ophthalmol       Date:  2018-08-22
  1 in total