Literature DB >> 24142780

Quality of spirometry in the elderly.

Małgorzata Czajkowska-Malinowska1, Waldemar Tomalak, Jakub Radliński.   

Abstract

INTRODUCTION: Spirometry is the basic method used to diagnose and monitor obstructive diseases. Spirometric tests are performed in more and more people of advanced age (more than 65 years old). The objective of the study was to assess the quality of spirometry (measurement of the flow-volume curve) in subjects of the aforementioned age group, with reference to applicable quality criteria specified in guidelines ERS/ATS 2005 and PTChP 2006.
MATERIAL AND METHODS: The study was of a retrospective nature. The authors analysed the results of spirometry performed in 1271 subjects who were 65 to 94 years old and who underwent spirometric tests in the Respiratory Physiopathology Laboratory of Kujawy-Pomorze Regional Centre of Pulmonology in Bydgoszcz over a period of 6 months. This group included 759 males (average age 73.2 ± 5.9 years) and 512 females (average age 73.2 ± 5.7 years). The quality of the spirometry was assessed according to error codes assigned to individual spirometric sessions by the software JLab 5.31 installed in the measuring system MasterScreen (CareFusion).
RESULTS: Twenty-nine (2.3%) of the 1271 subjects failed to perform spirometric measurements. For the remaining 1242 subjects the following spirometry quality was determined: correctly performed spirometric test in 415 (33.4%) subjects; one error in 673 (54.2%) subjects; 2 errors in 136 (11%) subjects; 3 errors in 15 (1.2%) subjects and 4 errors in 3 (0.2%) subjects. The analysis of individual errors revealed that the lack of a plateau at the end of exhalation was found in 747 (60.1%) subjects (including only 25 (2%) subjects with FET < 6 s); increased BEV value in 7 (0.6%) subjects; abruptly finished exhalation in 36 (2.9%) subjects; and no FVC and FEV₁ repeatability in 43 (3.5%) and 169 (13.6%) subjects, respectively.
CONCLUSIONS: The most common error was the lack of a plateau at the end of exhalation. Therefore, paying particular attention to the final phase of exhalation during spirometry should, as a result, increase the percentage of correctly performed spirometric tests in the elderly.

Entities:  

Mesh:

Year:  2013        PMID: 24142780

Source DB:  PubMed          Journal:  Pneumonol Alergol Pol        ISSN: 0867-7077


  12 in total

1.  [Lung function test in advanced age].

Authors:  Helmut Frohnhofen; Jeanina Schlitzer; Sven Stieglitz
Journal:  Z Gerontol Geriatr       Date:  2022-09-15       Impact factor: 1.292

2.  Respiratory Oscillometry in Chronic Obstructive Pulmonary Disease: Association with Functional Capacity as Evaluated by Adl Glittre Test and Hand Grip Strength Test.

Authors:  Caroline Oliveira Ribeiro; Agnaldo José Lopes; Pedro Lopes de Melo
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2022-05-04

3.  Predictors of poor-quality spirometry in two cohorts of older adults in Russia and Belgium: a cross-sectional study.

Authors:  Eralda Turkeshi; Dmitry Zelenukha; Bert Vaes; Elena Andreeva; Elena Frolova; Jean-Marie Degryse
Journal:  NPJ Prim Care Respir Med       Date:  2015-07-23       Impact factor: 2.871

4.  Association between the Type of Workplace and Lung Function in Copper Miners.

Authors:  Anna Skoczyńska; Leszek Gruszczyński; Anna Wojakowska; Marek Ścieszka; Barbara Turczyn; Edward Schmidt
Journal:  Biomed Res Int       Date:  2016-05-05       Impact factor: 3.411

5.  Clinical application value of impulse oscillometry in geriatric patients with COPD.

Authors:  Zhonghui Liu; Lianjun Lin; Xinmin Liu
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2017-03-15

6.  Use of the forced-oscillation technique to estimate spirometry values.

Authors:  Shoichiro Yamamoto; Seigo Miyoshi; Hitoshi Katayama; Mikio Okazaki; Hisayuki Shigematsu; Yoshifumi Sano; Minoru Matsubara; Naohiko Hamaguchi; Takafumi Okura; Jitsuo Higaki
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2017-10-03

7.  Prediction of Spirometric Indices Using Forced Oscillometric Indices in Patients with Asthma, COPD, and Interstitial Lung Disease.

Authors:  Seigo Miyoshi; Hitoshi Katayama; Minoru Matsubara; Takahide Kato; Naohiko Hamaguchi; Osamu Yamaguchi
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2020-07-01

8.  Evaluating the extremely elderly at a pulmonary function clinic for the diagnosis of respiratory disease: frequency and technical quality of spirometry.

Authors:  Saulo Maia d'Avila Melo; Larissa Alves de Oliveira; José Lucas Farias Wanderley; Rodrigo Dos Anjos Rocha
Journal:  J Bras Pneumol       Date:  2019-07-29       Impact factor: 2.624

9.  Standardization of Spirometry 2019 Update. An Official American Thoracic Society and European Respiratory Society Technical Statement.

Authors:  Brian L Graham; Irene Steenbruggen; Martin R Miller; Igor Z Barjaktarevic; Brendan G Cooper; Graham L Hall; Teal S Hallstrand; David A Kaminsky; Kevin McCarthy; Meredith C McCormack; Cristine E Oropez; Margaret Rosenfeld; Sanja Stanojevic; Maureen P Swanney; Bruce R Thompson
Journal:  Am J Respir Crit Care Med       Date:  2019-10-15       Impact factor: 21.405

10.  Application Value of Broadband 3-Dimensional Impulse Oscillometry in COPD.

Authors:  Zhonghao Tang; Minjing Li; Guokun Chu; Yan Mou; Qi Chen; Huili Zhu
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2021-02-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.