Literature DB >> 24134776

Detection of cobalt in synovial fluid from metal-on-metal hip prosthesis: correlation with the ion haematic level.

Alina Beraudi1, Simona Catalani, Monica Montesi, Susanna Stea, Alessandra Sudanese, Pietro Apostoli, Aldo Toni.   

Abstract

Hip replacement with large metal-on-metal (MoM) coupling has recently been under attention for its metal ions release, inducing several disorders. Since the blood level toxicity threshold for cobalt is known, the aim of this work is to determine whether Co serum and blood levels correlate with the synovial fluid level. Beside this, the synovial fluid Co from patients without prosthesis has also been measured. Co has been determined in 54 samples (32 unilateral MoM and 22 controls) with inductively coupled plasma mass spectrometry in the three matrices. In the prosthesized group, cobalt was significantly higher compared with controls and in the synovial fluid it strongly correlated with whole blood Co (p = 0.847) and serum (p = 0.855). Moreover, the Co levels into whole blood and serum were significantly different. In conclusion, haematic Co concentration correctly reflects Co local level.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24134776     DOI: 10.3109/1354750X.2013.846413

Source DB:  PubMed          Journal:  Biomarkers        ISSN: 1354-750X            Impact factor:   2.658


  4 in total

1.  Metal-on-metal hip prostheses: correlation between debris in the synovial fluid and levels of cobalt and chromium ions in the bloodstream.

Authors:  Dalila De Pasquale; Susanna Stea; Stefano Squarzoni; Barbara Bordini; Marilina Amabile; Simona Catalani; Pietro Apostoli; Aldo Toni
Journal:  Int Orthop       Date:  2014-03       Impact factor: 3.075

2.  Neuropsychiatric symptoms following metal-on-metal implant failure with cobalt and chromium toxicity.

Authors:  Ben Green; Emily Griffiths; Solomon Almond
Journal:  BMC Psychiatry       Date:  2017-01-24       Impact factor: 3.630

3.  In Vivo Damage of the Head-Neck Junction in Hard-on-Hard Total Hip Replacements: Effect of Femoral Head Size, Metal Combination, and 12/14 Taper Design.

Authors:  Massimiliano Baleani; Paolo Erani; Barbara Bordini; Federica Zuccheri; Mateusz Kordian Mąkosa; Dalila De Pasquale; Alina Beraudi; Susanna Stea
Journal:  Materials (Basel)       Date:  2017-07-01       Impact factor: 3.623

4.  Synovial Fluid Metal Ion Levels are Superior to Blood Metal Ion Levels in Predicting an Adverse Local Tissue Reaction in Failed Total Hip Arthroplasty.

Authors:  Matthew T Houdek; Michael J Taunton; Cody C Wyles; Paul J Jannetto; David G Lewallen; Daniel J Berry
Journal:  J Arthroplasty       Date:  2021-05-01       Impact factor: 4.435

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.