Recipient corneal thickness and visual outcome after Descemet's stripping automated endothelial keratoplasty.

Anders Ivarsen1, Jesper Hjortdal.   

Abstract

BACKGROUND: Descemet's stripping automated endothelial keratoplasty (DSAEK) is widely performed for endothelial failure. Unfortunately, the visual outcome is often mediocre and the underlying cause unclear. This study examines whether corneal light scatter and recipient corneal thickness (RCT) influence the visual outcome after DSAEK.
METHODS: Patients attending clinical control after DSAEK were recruited during 4 months. In total, 125 eyes from 93 patients were enrolled. Postoperative time averaged 20±13 months. Data from previous controls were also reviewed. Examinations included corrected distance visual acuity (CDVA), Pentacam and anterior-segment OCT. From OCT and Pentacam data, RCT and lamellar graft thickness (LGT) were determined. Corneal densitometry was estimated from Pentacam images.
RESULTS: 6 months after DSAEK, RCT measured 482±27 μm. After 3 years, RCT was significantly higher, measuring 505±23 μm. Pentacam and OCT showed similar variations in RCT. Also, in paired observations, from patients with previous controls, RCT increased significantly. Concurrently, corneal densitometry decreased and CDVA improved from 0.30±0.13 logMAR by 6 months to 0.17±0.08 logMAR by 4 years. No changes in LGT were observed. Changes in RCT, densitometry and CDVA were significantly correlated.
CONCLUSIONS: The study suggests that changes in RCT and corneal densitometry are important for the visual outcome after DSAEK.

Entities:  

Keywords:  Cornea; Dystrophy; Treatment Surgery

Mesh:

Year:  2013        PMID: 24133026     DOI: 10.1136/bjophthalmol-2013-304042

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  4 in total

1.  Outcome of Descemet stripping automated endothelial keratoplasty in eyes with an Ahmed glaucoma valve.

Authors:  Patrick J Chiam; Robert Cheeseman; Vivian W Ho; Vito Romano; Anshoo Choudhary; Mark Batterbury; Stephen B Kaye; Colin E Willoughby
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-03-17       Impact factor: 3.117

2.  Clinical study to estimate correlation between graft thickness as measured by anterior segment Optical Coherence Tomography and visual recovery after manual Descemet stripping endothelial keratoplasty.

Authors:  Rakesh Shetty; Jaya Kaushik; Arun Kumar; Ankita Singh
Journal:  Rom J Ophthalmol       Date:  2022 Apr-Jun

3.  Evaluation of interface reflectivity and corneal aberrations following Descemet's stripping automated endothelial keratoplasty.

Authors:  Hamid Khakshour; Malihe Nikandish; Maryam Salehi; Haleh Ghooshkhanehei; Amirhosein Vejdani
Journal:  Oman J Ophthalmol       Date:  2019 May-Aug

4.  Descemet stripping automated endothelial keratoplasty in Fuchs' corneal endothelial dystrophy: anterior segment optical coherence tomography and in vivo confocal microscopy analysis.

Authors:  Rita Mencucci; Eleonora Favuzza; Ruggero Tartaro; Massimo Busin; Gianni Virgili
Journal:  BMC Ophthalmol       Date:  2015-08-08       Impact factor: 2.209