Ihssan Al-Alem1, Krishna Pillai1, Javed Akhter1, Terence C Chua1, David L Morris2. 1. University of New South Wales, St George Hospital, Kogarah, New South Wales, Australia. 2. University of New South Wales, St George Hospital, Kogarah, New South Wales, Australia david.morris@unsw.edu.au.
Abstract
BACKGROUND: Radiofrequency ablation (RFA) is widely used for treating liver tumors; recurrence is common owing to proximity to blood vessels possibly due to the heat sink effect. We seek to investigate this phenomenon using unipolar and bipolar RFA on an egg white tumor tissue model and an animal liver model. MATERIALS AND METHODS: Temperature profiles during ablation (with and without vessel simulation) were studied, using both bipolar and unipolar RFA probes by 4 strategically placed temperature leads to monitor temperature profile during ablation. The volume of ablated tissue was also measured. RESULTS: The volume ablated during vessel simulation confirmed the impact of the heat sink phenomenon. The heat sink effect of unipolar RFA was greater compared with bipolar RFA (ratio of volume affected 2:1) in both tissue and liver models. The volume ablated using unipolar RFA was less than the bipolar RFA (ratio of volume ablated = 1:4). Unipolar RFA achieved higher ablation temperatures (122°C vs 98°C). Unipolar RFA resulted in tissue damage beyond the vessel, which was not observed using bipolar RFA. CONCLUSION: Bipolar RFA ablates a larger tumor volume compared with unipolar RFA, with a single ablation. The impact of heat sink phenomenon in tumor ablation is less so with bipolar than unipolar RFA with sparing of adjacent vessel damage.
BACKGROUND: Radiofrequency ablation (RFA) is widely used for treating liver tumors; recurrence is common owing to proximity to blood vessels possibly due to the heat sink effect. We seek to investigate this phenomenon using unipolar and bipolar RFA on an egg white tumor tissue model and an animal liver model. MATERIALS AND METHODS: Temperature profiles during ablation (with and without vessel simulation) were studied, using both bipolar and unipolar RFA probes by 4 strategically placed temperature leads to monitor temperature profile during ablation. The volume of ablated tissue was also measured. RESULTS: The volume ablated during vessel simulation confirmed the impact of the heat sink phenomenon. The heat sink effect of unipolar RFA was greater compared with bipolar RFA (ratio of volume affected 2:1) in both tissue and liver models. The volume ablated using unipolar RFA was less than the bipolar RFA (ratio of volume ablated = 1:4). Unipolar RFA achieved higher ablation temperatures (122°C vs 98°C). Unipolar RFA resulted in tissue damage beyond the vessel, which was not observed using bipolar RFA. CONCLUSION: Bipolar RFA ablates a larger tumor volume compared with unipolar RFA, with a single ablation. The impact of heat sink phenomenon in tumor ablation is less so with bipolar than unipolar RFA with sparing of adjacent vessel damage.
Authors: Yücel Korkusuz; Alexander Mader; Daniel Gröner; Shadi Ahmad; Oscar Maximilian Mader; Frank Grünwald; Christian Happel Journal: World J Surg Date: 2017-10 Impact factor: 3.352
Authors: Krishna Pillai; Javid Akhter; Terence C Chua; Mena Shehata; Nayef Alzahrani; Issan Al-Alem; David L Morris Journal: Medicine (Baltimore) Date: 2015-03 Impact factor: 1.889
Authors: Arthur J A T Braat; Julia E Huijbregts; I Quintus Molenaar; Inne H M Borel Rinkes; Maurice A A J van den Bosch; Marnix G E H Lam Journal: Front Oncol Date: 2014-07-30 Impact factor: 6.244
Authors: Kristina I Ringe; Carolin Lutat; Christian Rieder; Andrea Schenk; Frank Wacker; Hans-Juergen Raatschen Journal: PLoS One Date: 2015-07-29 Impact factor: 3.240