Literature DB >> 2413140

Cross-reactive urinary antigens among patients infected with Legionella pneumophila serogroups 1 and 4 and the Leiden 1 strain.

R B Kohler, L J Wheat, M L French, P L Meenhorst, W C Winn, P H Edelstein.   

Abstract

A solid-phase radioimmunoassay was developed to detect antigens of Legionella pneumophila serogroup 4. The assay detected antigen in urine from four of seven patients with pneumonia caused by L. pneumophila serogroup 4, two of two patients with L. pneumophila Leiden 1 strain (proposed new serogroup), and 26 of 55 patients with L. pneumophila serogroup 1 (proven by culture or direct fluorescent-antibody assay). The antigen of two patients with serogroup 4, one with Leiden 1 strain, and 49 with serogroup 1 infections could be detected in a previously described assay for antigens of L. pneumophila serogroup 1. Serogroup specificity of the assays could be demonstrated if serial dilutions of urine were tested. None of 347 urine specimens used as controls were positive in the radioimmunoassay. We conclude that antigens are excreted in the urine of at least some patients with Legionnaires' disease caused by serogroup 4 and Leiden 1 strain. The urinary antigens in patients with serogroup 4 and Leiden 1 strain infections, although different from those in patients with serogroup 1 infections, serologically contain cross-reactive components.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 2413140     DOI: 10.1093/infdis/152.5.1007

Source DB:  PubMed          Journal:  J Infect Dis        ISSN: 0022-1899            Impact factor:   5.226


  10 in total

1.  Comparison of radioimmunoassay and enzyme immunoassay kits for detection of Legionella pneumophila serogroup 1 antigen in both concentrated and nonconcentrated urine samples.

Authors:  J A Domínguez; L Matas; J M Manterola; R Blavia; N Sopena; F J Belda; E Padilla; M Giménez; M Sabrià; J Morera; V Ausina
Journal:  J Clin Microbiol       Date:  1997-06       Impact factor: 5.948

2.  Evaluation of the Binax and Biotest urinary antigen kits for detection of Legionnaires' disease due to multiple serogroups and species of Legionella.

Authors:  R F Benson; P W Tang; B S Fields
Journal:  J Clin Microbiol       Date:  2000-07       Impact factor: 5.948

3.  The role of arbitrarily primed PCR in identifying the source of an outbreak of Legionnaires' disease.

Authors:  C G Whitney; J Hofmann; J M Pruckler; R F Benson; B S Fields; U Bandyopadhyay; E F Donnally; C Giorgio-Almonte; L A Mermel; S Boland; B T Matyas; R F Breiman
Journal:  J Clin Microbiol       Date:  1997-07       Impact factor: 5.948

4.  Isolation of Legionella pneumophila serogroup 3 from pericardial fluid in a case of pericarditis.

Authors:  P C Lück; J H Helbig; E Wunderlich; H Foelske; M Selbitschka; D Wenzel; L Pätzold; W Witzleb
Journal:  Infection       Date:  1989 Nov-Dec       Impact factor: 3.553

5.  Comparison of the Binax Legionella urinary antigen enzyme immunoassay (EIA) with the Biotest Legionella Urin antigen EIA for detection of Legionella antigen in both concentrated and nonconcentrated urine samples.

Authors:  J A Domínguez; N Galí; P Pedroso; A Fargas; E Padilla; J M Manterola; L Matas
Journal:  J Clin Microbiol       Date:  1998-09       Impact factor: 5.948

6.  Retrospective evaluation of the Du Pont radioimmunoassay kit for detection of Legionella pneumophila serogroup 1 antigenuria in humans.

Authors:  M E Aguero-Rosenfeld; P H Edelstein
Journal:  J Clin Microbiol       Date:  1988-09       Impact factor: 5.948

Review 7.  Legionella and Legionnaires' disease: 25 years of investigation.

Authors:  Barry S Fields; Robert F Benson; Richard E Besser
Journal:  Clin Microbiol Rev       Date:  2002-07       Impact factor: 26.132

8.  Epidemiologic investigation by macrorestriction analysis and by using monoclonal antibodies of nosocomial pneumonia caused by Legionella pneumophila serogroup 10.

Authors:  P C Lück; J H Helbig; U Günter; M Assmann; R Blau; H Koch; M Klepp
Journal:  J Clin Microbiol       Date:  1994-11       Impact factor: 5.948

9.  The incidence of legionella pneumonia: a 1-year prospective study in a large community hospital.

Authors:  B Ruf; D Schürmann; I Horbach; F J Fehrenbach; H D Pohle
Journal:  Lung       Date:  1989       Impact factor: 2.584

10.  Broad-spectrum enzyme-linked immunosorbent assay for detection of Legionella soluble antigens.

Authors:  P W Tang; S Toma
Journal:  J Clin Microbiol       Date:  1986-10       Impact factor: 5.948

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.