Literature DB >> 24129983

Stress analysis in oral obturator prostheses over parallel and tilted implants: photoelastic imaging.

Aldiéris Alves Pesqueira1, Marcelo Coelho Goiato, Daniela Micheline dos Santos, Adhara Smith Nobrega, Marcela Filié Haddad, Agda Marobo Andreotti, Amália Moreno.   

Abstract

This study aimed to evaluate the stress distribution through the photoelastic method in implant-retained palatal obturators prostheses. Two photoelastic models with bucco-sinusal communication were fabricated, one model without implants and another with two parallel implants and one tilted in the molar region. A conventional obturator prosthesis and five implant-retained obturators dentures with different attachment systems were fabricated: OR, three individualized O-rings; BC, bar clip; BOC, implants splinted by bars associated with two O-rings positioned at the center of the bar; OD, implants splinted by bars associated with two O-rings positioned in distal cantilever; and BOD, implants splinted by bars with clips associated with two O-rings positioned in distal cantilever. Each assembly (model/attachment system/prosthesis) was positioned in a circular polariscope and a load of 100 N was applied on each implant. The results were obtained by observing the photographic record of the tensions in the photoelastic models resulting from the application of load. It can be observed that a larger amount of stress fringes on BC system. It was concluded that the attachment system has a direct influence on the stress distribution of implant-retained obturator prostheses, with the three individualized O-rings exhibiting the lowest stress values, and tilted implants presented a biomechanical behavior similar to parallel implants.

Entities:  

Mesh:

Year:  2013        PMID: 24129983     DOI: 10.1117/1.JBO.18.10.106009

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  2 in total

1.  Stress distribution of multiple implant-supported prostheses: Photoelastic and strain gauge analyses of external hexagon and morse taper connections.

Authors:  Ana-Beatriz-Bueno-Carlini Bittencourt; Erica-de Oliveira-Paiva Rezende; Marcio Campaner; Sandro-Basso Bitencourt; Daniela-Micheline Dos Santos; Aldiéris-Alves Pesqueira; Marcelo-Coelho Goiato
Journal:  J Clin Exp Dent       Date:  2022-03-01

2.  Dynamic UCLA for single tilted implant in an aesthetic region.

Authors:  Marcelo Coelho Goiato; Mariana Vilela Sônego; Emily Vivianne Freitas da Silva; Stefan Fiuza de Carvalho Dekon; Rodrigo Antonio de Medeiros; Karina Helga Turcio de Carvalho; Daniela Micheline Dos Santos
Journal:  Int J Surg Case Rep       Date:  2015-01-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.