Literature DB >> 24128369

Measurement of left and right atrial volume in patients undergoing ablation for atrial arrhythmias: comparison of a manual versus semiautomatic algorithm of real time 3D echocardiography.

Hajo Müller1, Stéphane Reverdin, Haran Burri, Dipen Shah, René Lerch.   

Abstract

AIMS: Real time full-volume 3D echocardiography (3DE) allows rapid and noninvasive measurement of left (LA) and right atrial (RA) volume without geometric assumptions. Different algorithms from different commercial providers are available. Older software requires manual tracing of endocardial contours. Recently, software with semiautomatic endocardial contour-finding algorithms has become available, which considerably speeds up the procedure. Our aim was to compare, in the same dataset, both LA and RA volumes determined by an algorithm involving manual tracing to the corresponding volumes obtained by an algorithm with semiautomatic contour detection.
METHODS: Maximal atrial volumes were measured in 88 patients using a multiplane interpolation method algorithm based on manual planimetry of 8 slices. These volumes were compared with volumes determined by the QLAB 8.1 software using semiautomatic border detection.
RESULTS: Linear regression showed excellent correlation between volumes determined by manual and by semiautomatic software for both LA and RA (r(2) = 0.90 and 0.89, respectively, P < 0.001). Bland-Altman analysis of manual versus semiautomatic volume determination showed narrow 95% limits of agreement (-15.9 to +12.0 mL for LA volume and -13.9 to +12.2 mL for RA volume) with a minimal bias of -1.9 ± 7.0 mL and -0.8 ± 6.5 mL, respectively, by the semiautomatic method.
CONCLUSION: The semiautomatic border detection method shows excellent correlation for maximal LA and RA volume determination compared to the more time-consuming, multiplane interpolation method, with only slight underestimation. The results indicate that values of LA and RA volumes obtained by either algorithm can be compared, for example, during follow-up examinations.
© 2013, Wiley Periodicals, Inc.

Entities:  

Keywords:  left atrial volume; right atrial volume; three-dimensional echocardiography

Mesh:

Year:  2013        PMID: 24128369     DOI: 10.1111/echo.12391

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  2 in total

1.  Mitral Valve Adaptation to Isolated Annular Dilation: Insights Into the Mechanism of Atrial Functional Mitral Regurgitation.

Authors:  Dae-Hee Kim; Ran Heo; Mark D Handschumacher; Sahmin Lee; Yun-Sil Choi; Kyu-Ri Kim; Yewon Shin; Hong-Kyung Park; Joyce Bischoff; Elena Aikawa; Jong-Min Song; Duk-Hyun Kang; Robert A Levine; Jae-Kwan Song
Journal:  JACC Cardiovasc Imaging       Date:  2017-12-13

2.  Right atrium size in the general population.

Authors:  Thomas Münzel; Philipp S Wild; Karsten Keller; Christoph Sinning; Andreas Schulz; Claus Jünger; Volker H Schmitt; Omar Hahad; Tanja Zeller; Manfred Beutel; Norbert Pfeiffer; Konstantin Strauch; Stefan Blankenberg; Karl J Lackner; Jürgen H Prochaska; Eberhard Schulz
Journal:  Sci Rep       Date:  2021-11-18       Impact factor: 4.379