Literature DB >> 24121624

Anterior screw fixation for an odontoid fracture using an Acutrak 4/5 screw: a case report.

Juichi Tonosu, Kenichi Watanabe, Hiroaki Abe, Akiro Higashikawa, Shinya Kato, Koji Yamada.   

Abstract

The direct anterior screw fixation of odontoid fractures by a single cancellous screw, especially for osteoporotic vertebrae, has a potential risk of leading to insufficient stability and implant failures. We experienced good results following surgery using a single Acutrak 4/5 screw to obtain sufficient stability for an odontoid fracture in a patient with osteopenia. The screw is a cannulated self-tapping headless screw and has a tapered profile and full threads with variable pitches, and it can yield sufficient compression force as the screw is inserted. The preoperative severe neck pain of the patient was diminished immediately after the surgery. The patient achieved bone union in a short time and had a good clinical result for at least 3 years. Some biomechanical studies showed that the compression force of Acutrak standard screws was stronger than that of both 4.0-mm cancellous screws inserted with the lag screw technique and Herbert screws, and other studies showed that the compression force of Acutrak 4/5 screws was equivalent to that of 4.5-mm cortical screws. However, there has been no clinical report of surgery using an Acutrak 4/5 screw for odontoid fractures. This is the first clinical report of fixation by an Acutrak 4/5 screw.

Entities:  

Mesh:

Year:  2013        PMID: 24121624     DOI: 10.1007/s00402-013-1870-y

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  2 in total

1.  A Review of Strategies to Improve Biomechanical Fixation in the Cervical Spine.

Authors:  Colby Oitment; Patrick Thornley; Frank Koziarz; Thorsten Jentzsch; Kunal Bhanot
Journal:  Global Spine J       Date:  2022-01-12

2.  Comparison between headless cannulated screws and partially threaded screws in femoral neck fracture treatment: a retrospective cohort study.

Authors:  Yilin Wang; Na Han; Dianying Zhang; Peixun Zhang; Baoguo Jiang
Journal:  Sci Rep       Date:  2022-02-02       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.