Literature DB >> 24121286

Confidence intervals for the parameters estimated from simulated O2 uptake kinetics: effects of different data treatments.

M P Francescato1, V Cettolo, R Bellio.   

Abstract

The behaviour of pulmonary O2 uptake following a moderate-intensity step exercise increment is usually described by a first brief increase, followed by a second exponential time course reaching the new steady state (phase II). The parameters describing the phase II kinetics are investigated by applying different data treatments to the acquired O2 uptake data to reduce the effects of their noise before running a non-linear regression procedure. The effects of different data treatments (nothing, resampling at various time intervals or averaging of more repetitions) on the precision and/or accuracy of the kinetics parameters estimated by non-linear regression with a simple mono-exponential model were investigated by artificially generating 10(5) simulated responses with average breath duration of 3.5 s. The simulations showed that, whatever the explored data treatment, the average estimated parameters were close to the theoretical ones. Nevertheless, in all the explored conditions, the non-linear regression provided narrower asymptotic confidence intervals than the real ones. In particular, when the responses were resampled at 1 s time intervals, the width of the asymptotic confidence interval for the time constant was 50% of the real one, even after the averaging of more repetitions. The reasons for this discrepancy were investigated further, allowing us to identify some methods to obtain the correct confidence interval of the O2 uptake kinetics parameters. The simplest method to obtain an asymptotic confidence interval close to the real one is to average more responses resampled to a time interval slightly longer than the average breath duration.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24121286     DOI: 10.1113/expphysiol.2013.076208

Source DB:  PubMed          Journal:  Exp Physiol        ISSN: 0958-0670            Impact factor:   2.969


  6 in total

1.  Interchangeability between two breath-by-breath O2 uptake calculation algorithms in asthmatic and healthy volunteers.

Authors:  Maria Pia Francescato; Mario Canciani; Valentina Cettolo
Journal:  Eur J Appl Physiol       Date:  2020-04-18       Impact factor: 3.078

Review 2.  Open-circuit respirometry: real-time, laboratory-based systems.

Authors:  Susan A Ward
Journal:  Eur J Appl Physiol       Date:  2018-05-04       Impact factor: 3.078

3.  Pulmonary oxygen uptake and muscle deoxygenation kinetics during heavy intensity cycling exercise in patients with emphysema and idiopathic pulmonary fibrosis.

Authors:  Melitta A McNarry; Nicholas K Harrison; Tom Withers; Narendra Chinnappa; Michael J Lewis
Journal:  BMC Pulm Med       Date:  2017-01-31       Impact factor: 3.317

4.  On correct computation of confidence intervals for kinetic parameters.

Authors:  Maria Pia Francescato; Valentina Cettolo; Ruggero Bellio
Journal:  Physiol Rep       Date:  2019-07

5.  Reply to Francescato et al.: on correct computation of confidence intervals for kinetic parameters.

Authors:  Richie P Goulding; Denise M Roche; Simon Marwood
Journal:  Physiol Rep       Date:  2019-07

6.  Training status affects between-protocols differences in the assessment of maximal aerobic velocity.

Authors:  Andrea Riboli; Susanna Rampichini; Emiliano Cè; Eloisa Limonta; Marta Borrelli; Giuseppe Coratella; Fabio Esposito
Journal:  Eur J Appl Physiol       Date:  2021-07-28       Impact factor: 3.078

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.