Literature DB >> 24120050

The biomechanical effect of increased valgus on total knee arthroplasty: a cadaveric study.

Brandon J Bryant1, Justin U Tilan1, Michelle H McGarry1, Nobuyuki Takenaka1, William C Kim1, Thay Q Lee1.   

Abstract

The effects of valgus load on cadaveric knees following total knee arthroplasty (TKA) were investigated using a custom testing system. TKAs were performed on 8 cadaveric knees and tested at 0°, 30°, and 60° knee flexion in both neutral and 5° valgus. Fuji pressure sensitive film was used to quantify contact areas and pressures and MCL strain was determined using a Microscribe digitizing system. Lateral tibiofemoral pressures increased (P < 0.05) at all knee flexion angles with valgus loading. Patellofemoral contact characteristics did not change significantly (P > 0.05). Significant increases in strain were observed along the anterior and posterior border of the MCL at all knee flexion angles. These findings suggest that valgus loading increases TKA joint contact pressures and MCL strain with increasing knee flexion which may increase implant instability.
© 2014.

Entities:  

Keywords:  MCL strain; patellofemoral contact; tibiofemoral contact; total knee arthroplasty; valgus

Mesh:

Year:  2013        PMID: 24120050     DOI: 10.1016/j.arth.2013.09.003

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Knee kinetics and kinematics: What are the effects of TKA malconfigurations?

Authors:  Silvia Pianigiani; Luc Labey; Walter Pascale; Bernardo Innocenti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-24       Impact factor: 4.342

2.  Kinematically aligned total knee arthroplasty reproduces native patellofemoral biomechanics during deep knee flexion.

Authors:  In Jun Koh; Il Jung Park; Charles C Lin; Nilay A Patel; Christen E Chalmers; Mauro Maniglio; Michelle H McGarry; Thay Q Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-28       Impact factor: 4.342

3.  Computational study on the effect of malalignment of the tibial component on the biomechanics of total knee arthroplasty: A Finite Element Analysis.

Authors:  D-S Suh; K-T Kang; J Son; O-R Kwon; C Baek; Y-G Koh
Journal:  Bone Joint Res       Date:  2017-11       Impact factor: 5.853

4.  Coronal alignment after total knee arthroplasty.

Authors:  Timothy Lording; Sébastien Lustig; Philippe Neyret
Journal:  EFORT Open Rev       Date:  2017-03-13

5.  Malpositioning of Prosthesis: Patient-specific Total Knee Arthroplasty Versus Standard Off-the-Shelf Total Knee Arthroplasty.

Authors:  Kyoung-Tak Kang; Juhyun Son; Oh-Ryong Kwon; Yong-Gon Koh
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2017-08-02

Review 6.  Influence of Menisci on Tibiofemoral Contact Mechanics in Human Knees: A Systematic Review.

Authors:  Matthias Sukopp; Florian Schall; Steffen P Hacker; Anita Ignatius; Lutz Dürselen; Andreas M Seitz
Journal:  Front Bioeng Biotechnol       Date:  2021-12-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.