Mandibular corrective osteotomy using novel locking compression plate 3.5/4.5/5.0 mm metaphyseal plates.

Christoph S Klaus1, Carsten Vogt, Christoph J Lischer.   

Abstract

OBJECTIVE: To describe a technique and the outcome of using 3.5/4.5/5.0 Metaphyseal Locking Compression Plate for corrective osteotomy of mandibular brachygnathia. STUDY
DESIGN: Clinical report. ANIMAL: Eight-month Thoroughbred horse.
METHODS: Severe mandibular brachygnathia was surgically treated by corrective osteotomy and fixation with 2 LCP 3.5/4.5/5.0 Metaphyseal plates inserted using minimally invasive technique.
RESULTS: Severe mandibular brachygnathia was treated successfully with minor complications and stable fixation after 3 months. Cosmetic outcome and owner satisfaction was excellent.
CONCLUSIONS: Corrective osteotomy and fixation with LCP 3.5/4.5/5.0 Metaphyseal plates can be considered as a surgical technique for correction of severe mandibular brachygnathia in weanlings. © Copyright 2013 by The American College of Veterinary Surgeons.

Entities:  

Mesh:

Year:  2013        PMID: 24117917     DOI: 10.1111/j.1532-950X.2013.12067.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  1 in total

1.  Treatment of class 2 malocclusion by corrective osteotomy using two short locking compression plates.

Authors:  T J P Spoormakers; P Wiemer
Journal:  Equine Vet J       Date:  2018-10-27       Impact factor: 2.888