Literature DB >> 24117798

Screening biological stains with qPCR versus lateral flow immunochromatographic test strips: a quantitative comparison using analytical figures of merit.

Crystal Simson Oechsle1, Sandra Haddad, Joanne B Sgueglia, Catherine M Grgicak.   

Abstract

Biological fluid identification is an important facet of evidence examination in forensic laboratories worldwide. While identifying bodily fluids may provide insight into which downstream DNA methods to employ, these screening techniques consume a vital portion of the available evidence, are usually qualitative, and rely on visual interpretation. In contrast, qPCR yields information regarding the amount and proportion of amplifiable genetic material. In this study, dilution series of either semen or male saliva were prepared in either buffer or female blood. The samples were subjected to both lateral flow immunochromatographic test strips and qPCR analysis. Analytical figures of merit-including sensitivity, minimum distinguishable signal (MDS) and limit of detection (LOD)-were calculated and compared between methods. By applying the theory of the propagation of random errors, LODs were determined to be 0.05 μL of saliva for the RSID™ Saliva cards, 0.03 μL of saliva for Quantifiler(®) Duo, and 0.001 μL of semen for Quantifiler(®) Duo. In conclusion, quantitative PCR was deemed a viable and effective screening method for subsequent DNA profiling due to its stability in different matrices, sensitivity, and low limits of detection.
© 2013 American Academy of Forensic Sciences.

Entities:  

Keywords:  DNA quantification; biological screening; forensic DNA analysis; forensic sciences; limit of detection; real-time polymerase chain reaction

Mesh:

Substances:

Year:  2013        PMID: 24117798     DOI: 10.1111/1556-4029.12284

Source DB:  PubMed          Journal:  J Forensic Sci        ISSN: 0022-1198            Impact factor:   1.832


  2 in total

1.  Y chromosome and HIV DNA detection in vaginal swabs as biomarkers of semen and HIV exposure in women.

Authors:  Kerri J Penrose; Barbra A Richardson; Guillaume Besson; Charlene S Dezzutti; Betsy C Herold; Salim S Abdool Karim; John W Mellors; Urvi M Parikh
Journal:  Sex Transm Dis       Date:  2014-11       Impact factor: 2.830

2.  Objective Measurement of Inaccurate Condom Use Reporting Among Women Using Depot Medroxyprogesterone Acetate for Contraception.

Authors:  Renee Heffron; Urvi M Parikh; Kerri J Penrose; Nelly Mugo; Deborah Donnell; Connie Celum; John W Mellors; Jared M Baeten
Journal:  AIDS Behav       Date:  2017-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.