BACKGROUND: Recently, measurement of amino terminal propeptide of type III procollagen (PIIINP) was introduced as a part of the hepatic cirrhotic marker enhanced liver fibrosis™ test on the automated ADVIA Centaur(®) immunoassay platform (Siemens Healthcare Diagnostics Inc., Tarrytown, NY, USA). In this article, we show that the Centaur PIIINP may be used in place of the much more labor-intensive RIA method, and we present an age stratified reference interval. METHODS: We analyzed four control samples 20 times over a period of 5 days. Centaur PIIINP assay measurements were compared with the widely used UniQ PIIINP RIA assay (Orion Diagnostica, Espoo, Finland) using 55 patient samples (range=3.7-43.3 µg/L). Furthermore, we established a reference interval based on samples from 287 blood donors. RESULTS: In the concentration range 2.5-11.9 µg/L, the total imprecision was below 8%. Comparison with the UniQ PIIINP RIA assay yielded: Centaur PIIINP µg/L = 1.9 × (UniQ PIIINP RIA) + 0.6 µg/L, r2=0.94. The reference interval for the Centaur PIIINP assay showed no gender difference but was stratified by age [4.0-11.0 µg/L (18-40 years) and 3.5-9.5 µg/L (41-70 years)]. CONCLUSIONS: We conclude that the Centaur PIIINP assay is suitable for routine use with our newly defined reference interval. The results obtained by Centaur correlates well with those obtained by the previously employed RIA, though the absolute values are higher.
BACKGROUND: Recently, measurement of amino terminal propeptide of type III procollagen (PIIINP) was introduced as a part of the hepatic cirrhotic marker enhanced liver fibrosis™ test on the automated ADVIA Centaur(®) immunoassay platform (Siemens Healthcare Diagnostics Inc., Tarrytown, NY, USA). In this article, we show that the Centaur PIIINP may be used in place of the much more labor-intensive RIA method, and we present an age stratified reference interval. METHODS: We analyzed four control samples 20 times over a period of 5 days. Centaur PIIINP assay measurements were compared with the widely used UniQ PIIINP RIA assay (Orion Diagnostica, Espoo, Finland) using 55 patient samples (range=3.7-43.3 µg/L). Furthermore, we established a reference interval based on samples from 287 blood donors. RESULTS: In the concentration range 2.5-11.9 µg/L, the total imprecision was below 8%. Comparison with the UniQ PIIINP RIA assay yielded: Centaur PIIINP µg/L = 1.9 × (UniQ PIIINP RIA) + 0.6 µg/L, r2=0.94. The reference interval for the Centaur PIIINP assay showed no gender difference but was stratified by age [4.0-11.0 µg/L (18-40 years) and 3.5-9.5 µg/L (41-70 years)]. CONCLUSIONS: We conclude that the Centaur PIIINP assay is suitable for routine use with our newly defined reference interval. The results obtained by Centaur correlates well with those obtained by the previously employed RIA, though the absolute values are higher.
Authors: Yi Luo; Abdul Oseini; Robert Gagnon; Edgar D Charles; Kurex Sidik; Robert Vincent; Rebeca Collen; Michael Idowu; Melissa J Contos; Faridoddin Mirshahi; Kalyani Daita; Amon Asgharpour; Mohammed S Siddiqui; Gabor Jarai; Glenn Rosen; Rose Christian; Arun J Sanyal Journal: Sci Rep Date: 2018-08-17 Impact factor: 4.379