Chronic measurement of left ventricular pressure in freely moving rats.

Ellyce Stehlin1, Simon C Malpas, David M Budgett, Carolyn J Barrett, Daniel McCormick, Gillian Whalley, Fumin Fu, Michael Beil, Dean F Rigel, Sarah-Jane Guild.   

Abstract

Measurements of left ventricular pressure (LVP) in conscious freely moving animals are uncommon, yet could offer considerable opportunity for understanding cardiovascular disease progression and treatment. The aim of this study was to develop surgical methods and validate the measurements of a new high-fidelity, solid-state pressure-sensor telemetry device for chronically measuring LVP and dP/dt in rats. The pressure-sensor catheter tip (2-Fr) was inserted into the left ventricular chamber through the apex of the heart, and the telemeter body was implanted in the abdomen. Data were measured up to 85 days after implant. The average daytime dP/dt max was 9,444 ± 363 mmHg/s, ranging from 7,870 to 10,558 mmHg/s (n = 7). A circadian variation in dP/dt max and heart rate (HR) was observed with an average increase during the night phase in dP/dt max of 918 ± 84 mmHg/s, and in HR of 38 ± 3 bpm. The β-adrenergic-agonist isoproterenol, β1-adrenergic agonist dobutamine, Ca(2+) channel blocker verapamil, and the calcium sensitizer levosimendan were administered throughout the implant period, inducing dose-dependent time course changes and absolute changes in dP/dt max of -6,000 to +13,000 mmHg/s. The surgical methods and new technologies demonstrated long-term stability, sensitivity to circadian variation, and the ability to measure large drug-induced changes, validating this new solution for chronic measurement of LVP in conscious rats.

Entities:  

Keywords:  dP/dt; inductive power; solid-state pressure; telemetry

Mesh:

Substances:

Year:  2013        PMID: 24114699     DOI: 10.1152/japplphysiol.00683.2013

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  2 in total

1.  Longitudinal hemodynamic measurements in swine heart failure using a fully implantable telemetry system.

Authors:  Jenny S Choy; Zhen-Du Zhang; Koullis Pitsillides; Margo Sosa; Ghassan S Kassab
Journal:  PLoS One       Date:  2014-08-13       Impact factor: 3.240

2.  Inhalation of printer-emitted particles impairs cardiac conduction, hemodynamics, and autonomic regulation and induces arrhythmia and electrical remodeling in rats.

Authors:  Alex P Carll; Renata Salatini; Sandra V Pirela; Yun Wang; Zhengzhi Xie; Pawel Lorkiewicz; Nazratan Naeem; Yong Qian; Vincent Castranova; John J Godleski; Philip Demokritou
Journal:  Part Fibre Toxicol       Date:  2020-01-29       Impact factor: 9.400

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.