Body surface area adapted iopromide 300 mg/ml versus 370 mg/ml contrast medium injection protocol: influence on quantitative and clinical assessment in combined PET/CT.

Frederik A Verburg1, Jonas Apitzsch, Carina Lensing, Christiane K Kuhl, Hubertus Pietsch, Felix M Mottaghy, Florian F Behrendt.   

Abstract

PURPOSE: To investigate the quantitative and qualitative differences between combined positron emission tomography and computed X-ray tomography (PET/CT) enhanced with contrast medium with either an iodine concentration 300 mg/ml or 370 mg/ml.
MATERIALS AND METHODS: 120 consecutive patients scheduled for F-18-Fluorodeoxyglucose (FDG) PET/CT were included. The first (second) 60 patients received contrast medium with 300 (370) mg iodine/ml. Intravenous injection protocols were adapted for an identical iodine delivery rate (1.3mg/s) and body surface area (BSA) adapted iodine dose (22.26 gI/m(2)). Maximum and mean standardized uptake values (SUV(max); SUV(mean)) and contrast enhancement (HU) were determined in the ascending aorta, the abdominal aorta, the inferior vena cava, the portal vein, the liver and the right kidney in the venous contrast medium phase. PET data were evaluated visually for the presence of malignancy and image quality.
RESULTS: Both media caused significantly higher values for HU, SUV(mean) and SUV(max) for the enhanced PET/CT than the non-enhanced one (all p<0.01). There were no significant differences in the degree of increase of HU, SUV(mean) and SUV(max) between the two contrast media at any anatomic site (all p>0.05). Visual evaluation of lesions showed no differences between contrast and non-contrast PET/CT or between the two different contrast media (p=0.77).
CONCLUSION: When using a constant iodine delivery rate and total iodine dose in a BSA adapted injection protocol, there are no quantitative or qualitative differences in either CT or PET between contrast media with an iodine concentration of 300 mg/ml and 370 mg/ml, respectively.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Attenuation correction; Contrast medium; PET/CT; Standardized uptake value

Mesh:

Substances:

Year:  2013        PMID: 24113432     DOI: 10.1016/j.ejrad.2013.09.013

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  2 in total

1.  Dual energy computed tomography analysis in cancer patients: What factors affect iodine concentration in contrast enhanced studies?

Authors:  Giuseppe Corrias; Peter Sawan; Usman Mahmood; Junting Zheng; Marinela Capanu; Marco Salvatore; Giacomo Spinato; Luca Saba; Lorenzo Mannelli
Journal:  Eur J Radiol       Date:  2019-10-03       Impact factor: 3.528

2.  Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography.

Authors:  Yan Xing; Gulina Azati; Cun-xue Pan; Jun Dang; Sailendra Jha; Wen-ya Liu
Journal:  PLoS One       Date:  2015-07-13       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.