Literature DB >> 24111283

Demonstrating the accuracy of an in-hospital ambulatory patient monitoring solution in measuring respiratory rate.

N Donnelly, T Hunniford, R Harper, A Flynn, A Kennedy, D Branagh, J McLaughlin.   

Abstract

This paper presents clinical testing conducted to evaluate the accuracy of Aingeal, a wireless in-hospital patient monitor, in measuring respiration rate via impedance pneumography. Healthy volunteers were invited to simultaneously wear a CE Marked Aingeal vital signs monitor and a capnograph, the current gold standard in respiration rate measurement. During the test, participants were asked to undergo a series of defined breathing protocols which included normal breathing, paced breathing between 8-23 breaths per minute (bpm) and a recovery period following moderate exercise. Statistical analysis of the data collected shows a mean difference of -0.73, a standard deviation of 1.61, limits of agreement of -3.88 and +2.42 bpm and a P-value of 0.22. This testing demonstrates comparable performance of the Aingeal device in measuring respiration rate with a well-accepted and widely used alternative method.

Entities:  

Mesh:

Year:  2013        PMID: 24111283     DOI: 10.1109/EMBC.2013.6611096

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  8 in total

Review 1.  A review of wearable technology in medicine.

Authors:  Mohammed H Iqbal; Abdullatif Aydin; Oliver Brunckhorst; Prokar Dasgupta; Kamran Ahmed
Journal:  J R Soc Med       Date:  2016-10       Impact factor: 5.344

Review 2.  Health Informatics via Machine Learning for the Clinical Management of Patients.

Authors:  D A Clifton; K E Niehaus; P Charlton; G W Colopy
Journal:  Yearb Med Inform       Date:  2015-08-13

3.  Preclinical evaluation of noncontact vital signs monitoring using real-time IR-UWB radar and factors affecting its accuracy.

Authors:  Jun-Young Park; Yonggu Lee; Ran Heo; Hyun-Kyung Park; Seok-Hyun Cho; Sung Ho Cho; Young-Hyo Lim
Journal:  Sci Rep       Date:  2021-12-08       Impact factor: 4.379

4.  Contact and Remote Breathing Rate Monitoring Techniques: A Review.

Authors:  Mohamed Ali; Ali Elsayed; Arnaldo Mendez; Yvon Savaria; Mohamad Sawan
Journal:  IEEE Sens J       Date:  2021-04-12       Impact factor: 4.325

5.  Use of wireless respiratory rate sensor monitoring during opioid patient-controlled analgesia after gynaecological surgery: A prospective cohort study.

Authors:  Shang-Ming Cheng; Jason Ju In Chan; Chin Wen Tan; Enhong Lu; Rehena Sultana; Ban Leong Sng
Journal:  Indian J Anaesth       Date:  2021-02-10

6.  Assessment of the feasibility of an ultra-low power, wireless digital patch for the continuous ambulatory monitoring of vital signs.

Authors:  Miguel Hernandez-Silveira; Kamran Ahmed; Su-Shin Ang; Fahriya Zandari; Tinaz Mehta; Rebecca Weir; Alison Burdett; Chris Toumazou; Stephen J Brett
Journal:  BMJ Open       Date:  2015-05-19       Impact factor: 2.692

7.  Continuous Monitoring of Respiratory Rate in Emergency Admissions: Evaluation of the RespiraSense™ Sensor in Acute Care Compared to the Industry Standard and Gold Standard.

Authors:  Christian Peter Subbe; Sean Kinsella
Journal:  Sensors (Basel)       Date:  2018-08-17       Impact factor: 3.576

8.  Algoritmically improved microwave radar monitors breathing more acurrate than sensorized belt.

Authors:  Andrzej Czyżewski; Bozena Kostek; Adam Kurowski; Krzysztof Narkiewicz; Beata Graff; Piotr Odya; Tomasz Śmiałkowski; Andrzej Sroczyński
Journal:  Sci Rep       Date:  2022-08-24       Impact factor: 4.996

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.