Literature DB >> 24111135

Wireless patch sensor for remote monitoring of heart rate, respiration, activity, and falls.

Alexander M Chan, Nandakumar Selvaraj, Nima Ferdosi, Ravi Narasimhan.   

Abstract

Unobtrusive continuous monitoring of important vital signs and activity metrics has the potential to provide remote health monitoring, at-home screening, and rapid notification of critical events such as heart attacks, falls, or respiratory distress. This paper contains validation results of a wireless Bluetooth Low Energy (BLE) patch sensor consisting of two electrocardiography (ECG) electrodes, a microcontroller, a tri-axial accelerometer, and a BLE transceiver. The sensor measures heart rate, heart rate variability (HRV), respiratory rate, posture, steps, and falls and was evaluated on a total of 25 adult participants who performed breathing exercises, activities of daily living (ADLs), various stretches, stationary cycling, walking/running, and simulated falls. Compared to reference devices, the heart rate measurement had a mean absolute error (MAE) of less than 2 bpm, time-domain HRV measurements had an RMS error of less than 15 ms, respiratory rate had an MAE of 1.1 breaths per minute during metronome breathing, posture detection had an accuracy of over 95% in two of the three patch locations, steps were counted with an absolute error of less than 5%, and falls were detected with a sensitivity of 95.2% and specificity of 100%.

Entities:  

Mesh:

Year:  2013        PMID: 24111135     DOI: 10.1109/EMBC.2013.6610948

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  16 in total

1.  A Pilot Study Evaluating the Physiological Parameters of Performance-Induced Stress in Undergraduate Music Students.

Authors:  Esther M van Fenema; Pim Gal; Maxime V van de Griend; Gabriel E Jacobs; Adam F Cohen
Journal:  Digit Biomark       Date:  2018-01-10

Review 2.  A Wearable Tele-Health System towards Monitoring COVID-19 and Chronic Diseases.

Authors:  Wei Jiang; Sumit Majumder; Samarth Kumar; Sophini Subramaniam; Xiaohe Li; Ridha Khedri; Tapas Mondal; Mansour Abolghasemian; Imran Satia; M Jamal Deen
Journal:  IEEE Rev Biomed Eng       Date:  2022-01-20

Review 3.  Performance Evaluation of Bluetooth Low Energy: A Systematic Review.

Authors:  Jacopo Tosi; Fabrizio Taffoni; Marco Santacatterina; Roberto Sannino; Domenico Formica
Journal:  Sensors (Basel)       Date:  2017-12-13       Impact factor: 3.576

4.  Estimating metabolic equivalents for activities in daily life using acceleration and heart rate in wearable devices.

Authors:  Motofumi Nakanishi; Shintaro Izumi; Sho Nagayoshi; Hiroshi Kawaguchi; Masahiko Yoshimoto; Toshikazu Shiga; Takafumi Ando; Satoshi Nakae; Chiyoko Usui; Tomoko Aoyama; Shigeho Tanaka
Journal:  Biomed Eng Online       Date:  2018-07-28       Impact factor: 2.819

5.  Validation of a wearable biosensor device for vital sign monitoring in septic emergency department patients in Rwanda.

Authors:  Stephanie C Garbern; Gabin Mbanjumucyo; Christian Umuhoza; Vinay K Sharma; James Mackey; Oliver Tang; Kyle D Martin; Francois R Twagirumukiza; Samantha L Rosman; Natalie McCall; Stephan W Wegerich; Adam C Levine
Journal:  Digit Health       Date:  2019-09-30

6.  A Pivotal Study to Validate the Performance of a Novel Wearable Sensor and System for Biometric Monitoring in Clinical and Remote Environments.

Authors:  Ellora Sen-Gupta; Donald E Wright; James W Caccese; John A Wright; Elise Jortberg; Viprali Bhatkar; Melissa Ceruolo; Roozbeh Ghaffari; Dennis L Clason; James P Maynard; Arthur H Combs
Journal:  Digit Biomark       Date:  2019-03-01

7.  Reliability of wireless monitoring using a wearable patch sensor in high-risk surgical patients at a step-down unit in the Netherlands: a clinical validation study.

Authors:  Martine J M Breteler; Erik Huizinga; Kim van Loon; Luke P H Leenen; Daan A J Dohmen; Cor J Kalkman; Taco J Blokhuis
Journal:  BMJ Open       Date:  2018-02-27       Impact factor: 2.692

8.  Current Evidence for Continuous Vital Signs Monitoring by Wearable Wireless Devices in Hospitalized Adults: Systematic Review.

Authors:  Jobbe P L Leenen; Crista Leerentveld; Joris D van Dijk; Henderik L van Westreenen; Lisette Schoonhoven; Gijsbert A Patijn
Journal:  J Med Internet Res       Date:  2020-06-17       Impact factor: 5.428

9.  Validation of a wireless patch sensor to monitor mobility tested in both an experimental and a hospital setup: A cross-sectional study.

Authors:  Niek Koenders; Joost P H Seeger; Teun van der Giessen; Ties J van den Hurk; Indy G M Smits; Anne M Tankink; Maria W G Nijhuis-van der Sanden; Thomas J Hoogeboom
Journal:  PLoS One       Date:  2018-10-25       Impact factor: 3.240

10.  Remote Patient Monitoring in Adults Receiving Transfusion or Infusion for Hematological Disorders Using the VitalPatch and accelerateIQ Monitoring System: Quantitative Feasibility Study.

Authors:  Rik Paulus Bernardus Tonino; Karen Larimer; Okke Eissen; Martin Roelof Schipperus
Journal:  JMIR Hum Factors       Date:  2019-12-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.