Literature DB >> 24110907

Using wearable UWB radios to measure foot clearance during walking.

Yongbin Qi, Cheong Boon Soh, Erry Gunawan, Kay-Soon Low, Arash Maskooki.   

Abstract

Foot clearance above ground is a key factor for a better understanding of the complicated relationship between falls and gait. This paper proposes a wearable system using UWB transceivers to monitor the vertical heel/toe clearance during walking. First, a pair of very small and light antennas is placed on a point approximating to the heel/toe of the foot, acting as a transmitter and receiver. Then, the reflected signal from ground is captured and propagation delay is detected using noise suppressed Modified-Phase-Only-Correlator (MPOC). The performance of the UWB-based system was compared with an ultrasound system for stationary movements. The experimental results show that an overall mean difference between these two systems is about 0.634mm with correlation coefficient value of 0.9604. The UWB-based system is then used to measure foot clearance during walking which shows promising results for gait events detection.

Mesh:

Year:  2013        PMID: 24110907     DOI: 10.1109/EMBC.2013.6610720

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  Estimation of spatial-temporal gait parameters using a low-cost ultrasonic motion analysis system.

Authors:  Yongbin Qi; Cheong Boon Soh; Erry Gunawan; Kay-Soon Low; Rijil Thomas
Journal:  Sensors (Basel)       Date:  2014-08-20       Impact factor: 3.576

Review 2.  Wireless Body Sensor Communication Systems Based on UWB and IBC Technologies: State-of-the-Art and Open Challenges.

Authors:  Ivana Čuljak; Željka Lučev Vasić; Hrvoje Mihaldinec; Hrvoje Džapo
Journal:  Sensors (Basel)       Date:  2020-06-25       Impact factor: 3.576

Review 3.  Gait Analysis in Parkinson's Disease: An Overview of the Most Accurate Markers for Diagnosis and Symptoms Monitoring.

Authors:  Lazzaro di Biase; Alessandro Di Santo; Maria Letizia Caminiti; Alfredo De Liso; Syed Ahmar Shah; Lorenzo Ricci; Vincenzo Di Lazzaro
Journal:  Sensors (Basel)       Date:  2020-06-22       Impact factor: 3.576

4.  Lower Extremity Joint Angle Tracking with Wireless Ultrasonic Sensors during a Squat Exercise.

Authors:  Yongbin Qi; Cheong Boon Soh; Erry Gunawan; Kay-Soon Low; Rijil Thomas
Journal:  Sensors (Basel)       Date:  2015-04-23       Impact factor: 3.576

5.  Gait analysis methods: an overview of wearable and non-wearable systems, highlighting clinical applications.

Authors:  Alvaro Muro-de-la-Herran; Begonya Garcia-Zapirain; Amaia Mendez-Zorrilla
Journal:  Sensors (Basel)       Date:  2014-02-19       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.