Literature DB >> 24110175

Detection of the optimal region of interest for camera oximetry.

Walter Karlen, J Mark Ansermino, Guy A Dumont, Cornie Scheffer.   

Abstract

The estimation of heart rate and blood oxygen saturation with an imaging array on a mobile phone (camera oximetry) has great potential for mobile health applications as no additional hardware other than a camera and LED flash enabled phone are required. However, this approach is challenging as the configuration of the camera can negatively influence the estimation quality. Further, the number of photons recorded with the photo detector is largely dependent on the optical path length, resulting in a non-homogeneous image. In this paper we describe a novel method to automatically detect the optimal region of interest (ROI) for the captured image to extract a pulse waveform. We also present a study to select the optimal camera settings, notably the white balance. The experiments show that the incandescent white balance mode is the preferable setting for camera oximetry applications on the tested mobile phone (Samsung Galaxy Ace). Also, the ROI algorithm successfully identifies the frame regions which provide waveforms with the largest amplitudes.

Entities:  

Mesh:

Year:  2013        PMID: 24110175     DOI: 10.1109/EMBC.2013.6609988

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  4 in total

1.  Prospective validation of smartphone-based heart rate and respiratory rate measurement algorithms.

Authors:  Sean Bae; Silviu Borac; Yunus Emre; Jonathan Wang; Jiang Wu; Mehr Kashyap; Si-Hyuck Kang; Liwen Chen; Melissa Moran; Julie Cannon; Eric S Teasley; Allen Chai; Yun Liu; Neal Wadhwa; Michael Krainin; Michael Rubinstein; Alejandra Maciel; Michael V McConnell; Shwetak Patel; Greg S Corrado; James A Taylor; Jiening Zhan; Ming Jack Po
Journal:  Commun Med (Lond)       Date:  2022-04-12

2. 

Authors:  Ward Seuntjens; Joris Schollaert; Ardavan Kashtiara; Wouter Platteau; Josefien van Olmen
Journal:  Huisarts Wet       Date:  2020-07-30

3.  New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring.

Authors:  Mark van Gastel; Sander Stuijk; Gerard de Haan
Journal:  Sci Rep       Date:  2016-12-07       Impact factor: 4.379

4.  Smartphone camera oximetry in an induced hypoxemia study.

Authors:  Jason S Hoffman; Varun K Viswanath; Caiwei Tian; Xinyi Ding; Matthew J Thompson; Eric C Larson; Shwetak N Patel; Edward J Wang
Journal:  NPJ Digit Med       Date:  2022-09-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.