The accurate assessment of visual field function can provide valuable information on a range of visual disorders. Saccadic Vector Optokinetic Perimetry (SVOP) is a novel instrument for measuring supra-threshold visual fields in young children who are otherwise unable to perform Automated Static Perimetry (ASP). However, limitations in Liquid Crystal Display (LCD) technology restrict the ability of SVOP to determine threshold values at various points in the visual field, often required in detailed perimetry examinations. This paper introduces a purpose-specific LCD luminance non-uniformity compensation approach to address this limitation. Thorough quantitative evaluation identifies the effectiveness of the proposed approach in (i) compensating for luminance non-uniformities across an LCD, and (ii) enabling SVOP to perform accurate and precise threshold visual field tests. The findings demonstrate that SVOP provides a promising alternative to the current threshold ASP standard (Humphrey Field Analyser).

Entities:  

Mesh:

Year:  2013        PMID: 24110017     DOI: 10.1109/EMBC.2013.6609830

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  4 in total

1.  Speed and accuracy of saccades in patients with glaucoma evaluated using an eye tracking perimeter.

Authors:  Andrew J Tatham; Ian C Murray; Alice D McTrusty; Lorraine A Cameron; Antonios Perperidis; Harry M Brash; Brian W Fleck; Robert A Minns
Journal:  BMC Ophthalmol       Date:  2020-06-30       Impact factor: 2.209

2.  The Assessment of Visual Fields in Infants Using Saccadic Vector Optokinetic Perimetry (SVOP): A Feasibility Study.

Authors:  Antonios Perperidis; Alice D McTrusty; Lorraine A Cameron; Ian C Murray; Harry M Brash; Brian W Fleck; Robert A Minns; Andrew J Tatham
Journal:  Transl Vis Sci Technol       Date:  2021-03-01       Impact factor: 3.283

3.  Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry.

Authors:  Ian C Murray; Lorraine A Cameron; Alice D McTrusty; Antonios Perperidis; Harry M Brash; Brian W Fleck; Robert A Minns
Journal:  Transl Vis Sci Technol       Date:  2016-08-31       Impact factor: 3.283

4.  Comparison of Saccadic Vector Optokinetic Perimetry and Standard Automated Perimetry in Glaucoma. Part I: Threshold Values and Repeatability.

Authors:  Ian C Murray; Antonios Perperidis; Lorraine A Cameron; Alice D McTrusty; Harry M Brash; Andrew J Tatham; Pankaj K Agarwal; Brian W Fleck; Robert A Minns
Journal:  Transl Vis Sci Technol       Date:  2017-09-06       Impact factor: 3.283

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.