Literature DB >> 24109644

An ergonomic, instrumented ultrasound probe for 6-axis force/torque measurement.

Matthew W Gilbertson, Brian W Anthony.   

Abstract

An ergonomic, instrumented ultrasound probe has been developed for medical imaging applications. The device, which fits compactly in the hand of sonographers and permits rapid attachment & removal of the ultrasound probe, measures ultrasound probe-to-patient contact forces and torques in all six axes. The device was used to measure contact forces and torques applied by ten professional sonographers on five patients during thirty-six abdominal exams. Of the three contact forces, those applied along the probe axis were found to be largest, averaging 7.0N. Measurement noise was quantified for each axis, and found to be small compared with the axial force. Understanding the range of forces applied during ultrasound imaging enables the design of more accurate robotic imaging systems and could also improve understanding of the correlation between contact force and sonographer fatigue and injury.

Entities:  

Mesh:

Year:  2013        PMID: 24109644     DOI: 10.1109/EMBC.2013.6609457

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  8 in total

1.  Three-Dimensional Surface Point Cloud Ultrasound for Better Understanding and Transmission of Ultrasound Scan Information.

Authors:  Joseph Nathaniel Stember
Journal:  J Digit Imaging       Date:  2018-12       Impact factor: 4.056

2.  Force-assisted ultrasound imaging system through dual force sensing and admittance robot control.

Authors:  Ting-Yun Fang; Haichong K Zhang; Rodolfo Finocchi; Russell H Taylor; Emad M Boctor
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-03-25       Impact factor: 2.924

3.  Intra-rater reliability of transversus abdominis measurement by a novice examiner: Comparison of "freehand" to "probe force device" method of real-time ultrasound imaging.

Authors:  Vanessa L Kennedy; Carol A Flavell; Kenji Doma
Journal:  Ultrasound       Date:  2019-02-25

4.  Dual Mode pHRI-teleHRI Control System with a Hybrid Admittance-Force Controller for Ultrasound Imaging.

Authors:  Teng Li; Xiao Meng; Mahdi Tavakoli
Journal:  Sensors (Basel)       Date:  2022-05-26       Impact factor: 3.847

5.  Toward Standardized Acoustic Radiation Force (ARF)-Based Ultrasound Elasticity Measurements With Robotic Force Control.

Authors:  Muyinatu A Lediju Bell; Shalki Kumar; Lily Kuo; H Tutkun Sen; Iulian Iordachita; Peter Kazanzides
Journal:  IEEE Trans Biomed Eng       Date:  2015-11-02       Impact factor: 4.538

Review 6.  The Need for Standardized Assessment of Muscle Quality in Skeletal Muscle Function Deficit and Other Aging-Related Muscle Dysfunctions: A Symposium Report.

Authors:  Rosaly Correa-de-Araujo; Michael O Harris-Love; Iva Miljkovic; Maren S Fragala; Brian W Anthony; Todd M Manini
Journal:  Front Physiol       Date:  2017-02-15       Impact factor: 4.566

7.  Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience.

Authors:  Michael O Harris-Love; Catheeja Ismail; Reza Monfaredi; Haniel J Hernandez; Donte Pennington; Paula Woletz; Valerie McIntosh; Bernadette Adams; Marc R Blackman
Journal:  PeerJ       Date:  2016-06-21       Impact factor: 2.984

8.  Reliability of body composition assessment using A-mode ultrasound in a heterogeneous sample.

Authors:  Monica Miclos-Balica; Paul Muntean; Falk Schick; Horia G Haragus; Bogdan Glisici; Vasile Pupazan; Adrian Neagu; Monica Neagu
Journal:  Eur J Clin Nutr       Date:  2020-09-11       Impact factor: 4.016

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.