Safety and efficacy of strategic implantable cardioverter-defibrillator programming to reduce the shock delivery burden in a primary prevention patient population.

Jonathan Buber1, David Luria, Osnat Gurevitz, David Bar-Lev, Michael Eldar, Michael Glikson.   

Abstract

AIMS: Strategically chosen ventricular tachycardia (VT)/ventricular fibrillation (VF) detection and therapy parameters aimed at reducing shock deliveries were proven effective in studies that utilized single manufacturer devices with a follow-up of up to 1 year. Whether these beneficiary effects can be generalized to additional manufacturers and be maintained for longer periods is to be determined. Our aim was to evaluate the durability and applicability of the programming of strategic implantable cardioverter-defibrillators (ICDs) of various manufacturers, which is aimed at reducing the shock delivery burden in primary prevention ICD recipients. METHODS AND
RESULTS: A retrospective analysis of prospectively collected data of 300 ICD recipients of various manufacturers was conducted; 160 devices were strategically programmed to reduce shocks and 140 were not. The primary endpoint was the composite of death and appropriate shocks. Additional outcomes were inappropriate shocks, syncope events, and non-sustained VTs. At a median follow-up of 24 months, 19 patients died, 31 received appropriate shocks, and 41 received inappropriate shocks. Multivariate analysis showed that strategic programming dedicated to shock reduction was associated with a 64% risk reduction in the primary endpoint [hazard ratio (HR): 0.13-0.93; P = 0.03] and a 70% reduction in inappropriate shock deliveries (HR: 0.16-0.72; P = 0.01). Very few syncope events occurred (five patients, 1.6%), and there was no between-group difference in this outcome.
CONCLUSION: Utilization of strategically chosen VT/VF detection and therapy parameters was found to be effective and safe in ICDs of various manufacturers at a median follow-up period of 2 years among primary prevention patients.

Entities:  

Keywords:  Implantable cardiac defibrillators; Inappropriate shocks; Strategic programming

Mesh:

Year:  2013        PMID: 24108231     DOI: 10.1093/europace/eut302

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  6 in total

Review 1.  [Fitness to drive in patients with cardiovascular implantable electronic devices].

Authors:  Dejan Mijic; Bernd Lemke; Harilaos Bogossian
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2019-05-09

Review 2.  Recommendations for driving after implantable cardioverter defibrillator implantation and the use of a wearable cardioverter defibrillator : Different viewpoints around the world.

Authors:  Mona Cooper; Theresa Berent; Johann Auer; Robert Berent
Journal:  Wien Klin Wochenschr       Date:  2020-05-20       Impact factor: 1.704

3.  Impact of the introduction of a standardised ICD programming protocol: real-world data from a single centre.

Authors:  Nicholas Sunderland; Amit Kaura; Anthony Li; Ravi Kamdar; Ed Petzer; Para Dhillon; Francis Murgatroyd; Paul A Scott
Journal:  J Interv Card Electrophysiol       Date:  2016-06-03       Impact factor: 1.900

Review 4.  Driving restrictions in patients with implantable cardioverter defibrillators and pacemakers.

Authors:  Eiichi Watanabe; Haruhiko Abe; Shigeyuki Watanabe
Journal:  J Arrhythm       Date:  2017-03-28

5.  Inappropriate implantable cardioverter defibrillator shocks-incidence, effect, and implications for driver licensing.

Authors:  Eiichi Watanabe; Katsunori Okajima; Akira Shimane; Tomoya Ozawa; Tetsuyuki Manaka; Itsuro Morishima; Toru Asai; Masahiko Takagi; Toshihiro Honda; Atsunobu Kasai; Eitaro Fujii; Kohei Yamashiro; Ritsuko Kohno; Haruhiko Abe; Takashi Noda; Takashi Kurita; Shigeyuki Watanabe; Hiroya Ohmori; Takashi Nitta; Yoshifusa Aizawa; Ken Kiyono; Ken Okumura
Journal:  J Interv Card Electrophysiol       Date:  2017-07-20       Impact factor: 1.900

6.  Nomogram predicting death and heart transplantation before appropriate ICD shock in dilated cardiomyopathy.

Authors:  Yu Deng; Nixiao Zhang; Wei Hua; Sijing Cheng; Hongxia Niu; Xuhua Chen; Min Gu; Chi Cai; Xi Liu; Hao Huang; Minsi Cai; Shu Zhang
Journal:  ESC Heart Fail       Date:  2022-01-22
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.